4.
Position the transceiver on an applicable surface for connection to the pole (Ref: Photo
2).
NOTE:
If the mounting flange has the correct fixing holes then the transceiver can be bolted onto
the pole without the use of the adapter ring
NOTE:
The isolation flange ring must be used if galvanic corrosion is a possibility (Ref:
Fig 1
).
NOTE:
Mount the transceiver on the end of a flanged pole using the flange adapter (Ref
Photo 3
).
If required contact Sonardyne Int Ltd.
Flange Adapter about to bolted to a pole
Photo 3
5.
Fit the O ring seals and anti extrusion rings to the isolation flange ring (Ref: Drawing in
Installation kit).
6.
Lubricate the O ring seals with petroleum jelly.
7.
Make sure the flange on the transceiver is clean and grease free.
8.
Fit the isolation flange ring to the transceiver and line up the mounting holes (Ref: Photo
4).