S201 AFM
3 - EMERGENCY PROCEDURES
3.4 - SMOKE AND FIRE
27/06/2019
SONAIR-S2-D-MAN-006
Page : 3-17
Rev. : A
3.4.2
ELECTRICAL FIRE
An electrical fire is often characterized by white smoke and an acrid smell.
1. Master switches
- BATT and ALT 2 off (see NOTE and
WARNING below).
2. Cabin heat
- close.
3. Fresh air venting
- open
4. In level flight you could slightly or totally open the canopy to allow fresh air
in (recommended max airspeed 100 KIAS
–
see note below)
See continued procedure on next page
–
WARNING
The Engine Monitoring System, the radio and the transponder are not
operational when the master switch is off.
NOTE
Engine will continue to run with Master switch off, as long as ignition is on,
providing power is supplied to Main Fuel pump by the Alternator 1 or the
Battery (see electrical system description in section
Erreur ! Source du r
envoi introuvable.
).
NOTE
Flying with canopy open is forbidden in normal condition. In case of
emergency, canopy can be open up to 100 kts. When opening, higher pull
force than usual is required to slide backward the first 20 cm. Once open, it
can be easily maintained in position and closed afterward.
Содержание S201
Страница 100: ...S201 AFM 3 EMERGENCY PROCEDURES 3 10 OTHER EMERGENCIES 27 06 2019 SONAIR S2 D MAN 006 Page 3 38 Rev A ...
Страница 101: ...S201 AFM 3 EMERGENCY PROCEDURES 3 10 OTHER EMERGENCIES 27 06 2019 SONAIR S2 D MAN 006 Page 3 39 Rev A ...
Страница 242: ...S201 AFM 7 AIRPLANE AND SYSTEMS DESCRIPTION 7 9 POWERPLANT 27 06 2019 SONAIR S2 D MAN 006 Page 7 75 Rev A ...
Страница 252: ...S201 AFM 7 AIRPLANE AND SYSTEMS DESCRIPTION 7 11 ELECTRICAL SYSTEM 27 06 2019 SONAIR S2 D MAN 006 Page 7 85 Rev A ...