S201 AFM
3 - EMERGENCY PROCEDURES
3.10 - OTHER EMERGENCIES
27/06/2019
SONAIR-S2-D-MAN-006
Page : 3-42
Rev. : A
3.10.10
BACKUP INSTRUMENT MALFUNCTION
•
Sensor failure
If any internal sensor fails, the corresponding parameter on the display will
remain in the Red-
X’ed state. If this occurs, the unit must be returned to th
e
factory for service.
•
Memory error
On power-on, the unit performs a self-test of the calibration and setup
parameters stored in nonvolatile memory. If this test fails, a red MEMORY ERROR
message is displayed and the instrument becomes inoperable. If this occurs, the
unit must be returned to the factory for service.
•
Degraded Attitude
During mode, errors in pitch or roll may be observed during long accelerations
or decelerations, however attitude information is always available - it is never
removed or made un-available. Errors will not exceed TSO limit specifications.
When a cross check message is present the KI 300 is considered to be in
degraded mode. The TSO tested maneuvers represent typical flight. Degraded
mode may occur if a pilot maintains an accelerated frame of reference (i.e. turns)
for greater than 3 minutes. Degraded Mode maintains basic attitude
Содержание S201
Страница 100: ...S201 AFM 3 EMERGENCY PROCEDURES 3 10 OTHER EMERGENCIES 27 06 2019 SONAIR S2 D MAN 006 Page 3 38 Rev A ...
Страница 101: ...S201 AFM 3 EMERGENCY PROCEDURES 3 10 OTHER EMERGENCIES 27 06 2019 SONAIR S2 D MAN 006 Page 3 39 Rev A ...
Страница 242: ...S201 AFM 7 AIRPLANE AND SYSTEMS DESCRIPTION 7 9 POWERPLANT 27 06 2019 SONAIR S2 D MAN 006 Page 7 75 Rev A ...
Страница 252: ...S201 AFM 7 AIRPLANE AND SYSTEMS DESCRIPTION 7 11 ELECTRICAL SYSTEM 27 06 2019 SONAIR S2 D MAN 006 Page 7 85 Rev A ...