![SOMFY SONESSE 30 WF RTS LI-ION Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/somfy/sonesse-30-wf-rts-li-ion/sonesse-30-wf-rts-li-ion_instructions-manual_1317694005.webp)
5
Copyright © 2017
SOMFY ACTIVITES SA
. All rights reserved
EN
SONESSE 30 WF RTS LI-ION
1
1
2. 3. 4. Setting the end limits
"
The end limits can be set in any order.
1) Press and hold the UP button to move the driven
product to the desired Up position. If necessary,
adjust the Up position using the UP or DOWN buttons.
2)
To memorize the UP limit
: Press the
MY and DOWN buttons simultaneously and
release once the driven product begins to move.
The Up limit is now memorized.
3) Press the MY button when the driven product
reaches the desired Down position. If necessary,
adjust the down position using the UP or DOWN
buttons.
4)
To memorize the Down limit
: Press the MY
and UP buttons simultaneously and release when
the driven product begins to move. The Down limit
is now memorized. The driven product moves up and
will stop at its upper limit.
5)
To confirm and complete limit programming
: Press and hold the MY button until the driven product
briefly moves Up and Down. The end limits are now recorded.
2. 3. 5. Activate/Deactivate “RTS” radio technology when control point is temporarily preprogrammed
(not paired) to the driven product.
"
This function is used to deactivate the radio transmission to save the battery life during shipment, or when the
product will not be used for an extended amount of time (ex: storage).
1) To deactivate the “RTS” Radio Technology Somfy,
press the UP, MY and DOWN buttons simultaneously,
until the driven product briefly moves Up and Down
once.
2) To activate the “RTS” Radio Technology Somfy,
briefly press the motor head programming button,
the driven product briefly moves Up and Down three
times.
2. 3. 6. Recording “Pairing” the control point
AGer recording the end limits:
Briefly press the control point programming button. The
driven product will briefly move Up and Down to confirm
pairing.
The
control point
is recorded “paired” to driven
product.
1
2
3
4
5
1
2
3x
PROG.