3. 6. ADJUSTING THE SPEED
"
LED blinks alternately in green and Yellow.
1) Move the driven product away from the end limits.
Press and hold the UP, MY and DOWN buttons
simultaneously, until the driven product briefly
moves Up and Down once. The driven product will
move UP and Down automatically in ten second
cycles.
2) To increase the speed, press and hold the UP button
until the driven product briefly moves Up and Down.
Repeat as needed.
"
Maximum speed is achieved when the driven
product no longer responds to the press of the UP
button.
3) To decrease the speed, press and hold the DOWN button until the driven product briefly moves Up and Down.
Repeat as needed.
"
Minimum speed is achieved when the driven product no longer responds to the press of the DOWN button.
4) To confirm the new speed, press and hold the MY button until the driven product briefly moves Up and Down.
3. 7. TIPS AND ADVICE ON OPERATION
Observations
Possible causes
Solutions
The driven product
does not operate.
The thermal protection has activated.
Wait for the drive to cool down.
The control point battery is low.
Change battery as required.
3. 7. 1. Adding/Deleting Control point
"
Green LED blinks fast when adding or deleting remote control
Using a control point (A) that has been previously programmed to the driven product:
1) Press and hold the control point programming
button (A) until driven product briefly moves Up and
Down.
2) Quickly press the programming button on the back
of the new control point (B) to add or delete control
point.
Using the Programming button on motor head:
1) Press and hold the motor head programming button
until driven product briefly moves Up and Down.
2) Quickly press the control point programming button
(B) to add or delete control point.
1
2
3
4
10s
10s
A
B
A
A
A
B
B
1
2
PROG.
A
PROG.
B
1
2
A
PROG.
B