4
EN
Copyright © 2018 SOMFY ACTIVITÉS SA, Société Anonyme. All rights reserved
.
1
2. INSTALLATION
Instructions which
must
be followed by the drive and home automation professional installing the Movelite
TM
motor.
Never drop, knock, drill or submerge the drive.
Install a separate control point for each drive.
Safety warning!
Information
Caution!
2.2. WIRING
(Fig C)
Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
Attach cables to prevent any contact with moving parts.
Leave the drive power supply cable accessible: it must be possible to replace it easily.
-
Switch off the power supply.
-
Connect the drive according to the information in the table below:
AC wiring
(Fig C1)
DCT wiring
(Fig C2)
Compatible controls - Wiring of control (Fig D)
1) Setting tool
2) Centralis IB
3) 2 NO (Normally Open) Dry contact switch
2.3. COMMISSIONING
2.3.1. Pre-programming the RTS control point (only for RTS version) (Fig E)
1)Switch on the power supply
2) Press the
Open
and
Close
buttons on the RTS control point at the same time: The motorised product moves up and
down, and the RTS control point is pre-programmed in the motor.
2.1. INSTALLATION
2.1.1. Installation of the rail (Fig A)
1) Mark the position of the brackets.
2) Drill the ceiling or the wall at the right places.
3) Attach the brackets.
4) Attach the rail on the brackets.
2.1.2. Installation of the motor (Fig B)
1) Unlock the motor
2) Insert the motor sha into the drive pulley hole.
3) Lock the motor.
1
CCW (Open) NO Dry contact
4
2
5
Stop - NO Dry contact
3
Ground Common
6
CW (Close) NO Dry contact
Open
my/Stop
Close
DCT Setting tool
RTS control point
1
For the illustration, see page 122.
Wire
100V to 240V
1
Neutral
Blue
2
Live
Brown
3
Earth
Yellow / Green