2.1.5. Mounting the tube-drive assembly

Fit and attach the tube-drive assembly to the end bracket 

f

 and the 

drive bracket 

g

.

Attention

Ensure that the drive-tube assembly is secured onto the end 

bracket. This operation prevents the drive-tube assembly from 

coming out of the end bracket mounting.

2.2. WIRING

Attention

•  Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
•  Attach cables to prevent any contact with moving parts.
•  If the drive is used outdoors, and if the power supply cable is a type H05-VVF cable, the cable should be 

installed in a UV-resistant duct, e.g. under a gland.

•  The ILMO2 50 VSI WT cable can be removed. If it becomes damaged, replace it with an identical cable.
•  Leave the drive power supply cable accessible: it must be easy to replace.
•  Always make a loop in the power supply cable to prevent water entering the drive!

 - Switch off the power supply.
 - Connect the drive and the control point according to the in-

formation provided in the table below.

230 V

   

50 Hz

1

Neutral (N)

Blue

2

Live (up or down) (L)

Brown

3

Live (up or down) (L)

Black

4

Earth

Green/Yellow

͉

͉

Depending on the maximum load current of the control point and depending on the types of motors, several motors 

can be connected in parallel to a single control point.

͉

͉

To integrate a motor into a Somfy system, using a Somfy motor controller, the connection requirements in the 

controller manual must be followed carefully.

͉

͉

Control points with a “semi-conductor” relay must not be used.

f

g

L ≤ 50 m

4

230 V 

 50 Hz

1 2 3

OFF

Содержание ilmo2 50 WT

Страница 1: ...ILMO2 50 CSI WT Notice Instructions Anleitung Istruzioni FR EN DE IT...

Страница 2: ......

Страница 3: ...imm diatement la mort ou des blessures graves Avertissement Signale un danger susceptible d entra ner la mort ou des blessures graves Pr caution Signale un danger susceptible d entra ner des blessures...

Страница 4: ...ilisation et de maintenance de la motorisation et doit leur transmettre les instructions d utilisation et de maintenance ainsi que le document joint Consignes de s curit apr s l installation de la mot...

Страница 5: ...selon les cotes suivantes d 4 mm e 28 mm 2 1 3 Assemblage motorisation tube 1 Glisser la motorisation dans le tube d enroulement Pour les tubes d enroulement lisses l int rieur positionner l encoche d...

Страница 6: ...nt aux UV par exemple sous goulotte Le c ble de l ILMO2 50 VSI WT est d montable S il est endommag le remplacer l identique Laisser le c ble d alimentation de la motorisation accessible elle doit pouv...

Страница 7: ...se Les protections m caniques sont par exemple des but es robustes pour la fin de course haute et une quantit suffisante de liens rigides pour la fin de course basse minimum 5 1 R tablir l alimentatio...

Страница 8: ...er que le produit motoris est quip de but es viss es sur la lame finale de but es fixes ou amovibles int gr es dans les coulisses ou d une lame finale faisant office de but e 2 4 2 Retour en configura...

Страница 9: ...tion de la manivelle de secours en tournant l g rement et faire une marque sur la manivelle pour indiquer le sens de rotation pour ouvrir le volet roulant 3 Tourner la manivelle pour monter ou descend...

Страница 10: ...givre le fonctionnement de la protection contre le gel peut en revanche tre limit Dans ce cas un endommagement du tablier n est pas compl tement exclu Ce type de gel du tablier est tr s rare Si cela...

Страница 11: ...tes a danger which may result in immediate death or serious injury Warning Indicates a danger which may result in death or serious injury Precaution Indicates a danger which may result in minor or mod...

Страница 12: ...solves Somfy of any liability and invalidates the warranty The installer must inform its customers of the operating and maintenance conditions for the drive and must provide them with the operating an...

Страница 13: ...d 4 mm e 28 mm 2 1 3 Drive tube assembly 1 Slide the drive into the roller tube For roller tubes which are smooth inside position the notch previously cut on the boss on the crown 2 The drive wheel m...

Страница 14: ...a gland The ILMO2 50 VSI WT cable can be removed If it becomes damaged replace it with an identical cable Leave the drive power supply cable accessible it must be easy to replace Always make a loop i...

Страница 15: ...be assured Mechanical protection are e g robust stoppers for the upper end limit and a sufficient quantity minimum 5 of rigid links 1 Restore the mains power supply Press the Up button at the control...

Страница 16: ...uitable Check that the motorised product is fitted with end stops screwed onto the last slat fixed or removable stops incorporated in the runners or an end slat acting as an end stop 2 4 2 Restoring t...

Страница 17: ...ofrotationoftheemergencycrankbyturningit slightlyandmakeamarkonthecranktoindicatethedirectionofrota tioninordertoopen the rollershutter 3 Turn the crank to raise or lower the motorised product Procedu...

Страница 18: ...may reduce the effectiveness of the antifreeze protection In this event it is still possible that damage may be caused to the shutter It is very rare for the shutter to become frozen in this way In su...

Страница 19: ...r hin die sofort zu schweren bis t dlichen Verletzungen f hrt Warnung Weist auf eine Gefahr hin die zu schweren bis t dlichen Verletzungen f hren kann Vorsicht Weist auf eine Gefahr hin die zu leichte...

Страница 20: ...ebshinzuweisenundihnendiese sowie das beiliegende Dokument Sicherheitshinweise nach Abschluss der Installation des Antriebs auszuh ndigen Gegebenenfalls erforderliche Kundendiensteingriffe auf dem Ant...

Страница 21: ...sind mit einer Ausklinkung mit folgenden Ma en d 4 mm e 28 mm 2 1 3 Zusammenbau von Antrieb und Welle 1 F hren Sie den Antrieb in die Welle ein Positionieren Sie bei auf der Innenseite glatten Wellen...

Страница 22: ...t wird muss dieses in einem UV best ndigen Kabelrohr zum Beispiel in einem Kabelkanal verlegt werden Das Kabel des ILMO2 50 VSI WT l sst sich abnehmen Wenn es besch digt wurde muss es durch ein gleich...

Страница 23: ...r die obere Endlage robuste Endstab Stopper und f r die untere Endlage eine ausreichende Zahl mind 5 St ck feste Wellenverbinder sein 1 Schalten Sie die Spannungsversorgung wieder ein z B Sicherung e...

Страница 24: ...verschraubt sind ob feste oder abnehmbare Anschl ge in die F hrungsschienen integriert sind oder ob die letzte Lamelle als Anschlag fungiert 2 4 2 R cksetzung auf Werkseinstellung 2 4 2 1 Mit der Bedi...

Страница 25: ...rch leichtes Drehen Es empfiehlt sich bei der erstmaligen Nutzung der Kurbel eine Markierung anzubringen die die korrekte Drehrichtung anzeigt 3 Drehen Sie die Nothandkurbel um den Behang ein oder aus...

Страница 26: ...eschr nkt sein In diesem Fall ist eine Besch digung des Panzers nicht v llig ausgeschlossen Ein derartiges Einfrieren des Panzers ist sehr selten Warten Sie in diesem Fall das Abtauen ab bevor Sie den...

Страница 27: ...e causa immediatamente il decesso o gravi lesioni fisiche Avvertenza Segnala un pericolo che pu causare il decesso o gravi lesioni fisiche Precauzione Segnala un pericolo che pu causare lesioni fisich...

Страница 28: ...in relazione alle condizioni d uso e di manutenzione della motorizzazione e deve consegnare loro le istruzioni d uso e di manutenzione oltre al documento allegato Istruzioni di sicurezza dopo l insta...

Страница 29: ...care una tacca rispettando le misure indicate d 4 mm e 28 mm 2 1 3 Assemblaggio motorizzazione tubo 1 Infilare la motorizzazione nel tubo di avvolgimento Per i tubi di avvolgimento lisci all interno p...

Страница 30: ...O2 50 CSI WT pu essere smontato Se danneggiato sostituirlo con uno identico Lasciare libero l accesso al cavo d alimentazione della motorizzazione la quale deve poter essere sostituita facilmente Form...

Страница 31: ...e corsa Le protezioni meccaniche possono essere degli stopper resistenti per il fine corsa superiore e una quantit sufficiente di cintini rigidi per il fine corsa inferiore minimo 5 1 Riattivare l ali...

Страница 32: ...dotato di stopper avvitati sulla stecca finale fissi o rimovibili integrati nelle guide o di una stecca finale che funge da fine corsa 2 4 2 Ritorno alla configurazione originale 2 4 2 1 Utilizzando i...

Страница 33: ...adiemergenza ruotandola leggermente e fare un segno sopra la manovella per indicare il senso di rotazione per aprire la tapparella 3 Ruotare l asta per far salire o scendere il prodotto motorizzato Pr...

Страница 34: ...loro dal ghiaccio possibile che vi siano delle limitazioni nel funzionamento della protezione antigelo In tal caso non da escludere del tutto un danneggiamento del telo Questo tipo di congelamento del...

Страница 35: ......

Страница 36: ...TIVIT S SA 50 avenue du Nouveau Monde F 74300 Cluses www somfy com 5146345A 5146345A SOMFY ACTIVIT S SA Soci t Anonyme capital 35 000 000 Euros RCS Annecy 303 970 230 02 2019 Images not contractually...

Отзывы: