4 cm
On a 3 x 1.5 mm² type cable, prepare 2 4 cm wires (phase and
neutral)
1
Connect phase and neutral to terminals 16 and 17 (red "230 V"
label)
2
Immobilise the 230 V power cable with the cable-clamp
provided (18).
Fit a terminal block on the earth wire (yellow/green) and store
it in the control unit.
ANT
ANT
BUS
BUS
1
1
3
3
2
2
4
4
5
5
6
6
START
ART
M1
M1
M2
M2
11
11
13
13
10
10
12
12
BATT
BATT
+
+
-
-
LIGHT
LIGHT
230V
230V
15
15
17
17
14
14
16
16
7
7
-
FLASH
8
8
9
9
24V
+
L
L
N
N
Neutral
Live
Live
Neutral
230V power supply cable
230V power supply cable
Connecting to the mains power supply
6
For your safety, these operations must be carried out with the power supply switched off.
Use a 3 1.5 x 1.5 mm² cable for outdoor use (at least H07RN type).
The cable clamp supplied must be used. For low-voltage cables, ensure that they can resist a tensile force of 100 N.
Check that the conductors have not moved when this force is applied.
Cable clamp
Connecting the control unit to the mains power