2.4 Securing the control unit to the pillar
1
2
3
Position the unit mounting bracket against
the pillar/wall.
Check that it is horizontal by placing a spirit
level in the intended location.
Secure the bracket to the pillar/wall.
Secure the base of the unit to the pillar/wall:
1 screw to secure the unit to the b 2
screws to secure the unit to the pillar/wall.
CONNECTING THE MOTORS 3
Motor M1 activates the gate leaf which
•
opens first and closes last,
•
opens for pedestrian access.
1
M1 est à gauche
OU
M1 est à droite
M1 on the le
M1 on the right
With the gate closed, identify the gate
leaf that opens first.
Motor M1 activates this gate leaf.
2
Connect the motors as indicated in the table below:
Connect motor wire...
to terminal ...
M1
blue
10
brown
11
M2
blue
12
brown
13
M1
M1
M2
M2
11
11
13
13
10
10
12
12
BATT
BATT
+
+
-
-
FLASH
8
8
9
9
24V
+