11
EN
Elixo 500 24 V
If the parameters are changed after self-learning has been carried out, ensure the installation conforms to all
relevant standards.
ParamEtEr sEttiNG
menu [display]
value
By
default
Comments
Language [LAnGUAGE]: to select the language for displaying information on the control unit screen.
french [fra]
fra
English [Eng]
Spanish [Esp]
German [Deu]
Italian [Ita]
Self-learning [AutoSet]: to start self-learning for the gate travel.
Parameters [PArAM]: to change the torque, speed and slowing down values for the motorisation.
Automatic closure time
[tcA]
Between 3 and 120 seconds
10 s
Setting the time delay for automatic reclosing (If tcA is activated in
LoGic)
Opening motor torque
[oP. t]
Between 1% and 99%
80%
The setting for the minimum motor torque value needed to move the
gate is carried out during auto-programming.
Refer to the paragraph entitled “Display of the motor torque values
during operation of the motorisation”
pg. 13 to set the motor torque
values.
Closing motor torque
[cLS.t]
Between 1% and 99%
80%
Opening motor torque
while slowing down
[oP. t Slow]
Between 1% and 99%
50%
Closing motor torque
while slowing down
[cLS. t SLow]
Between 1% and 99%
50%
Normal opening speed
time [norM. oP. SPEED]
Between 1 second and 2
minutes
15 s
The slowing down time during opening and closing can be set by
changing the “normal speed time”; the higher the normal speed
travel, the shorter the slowing down time.
E.g.: if the duration of an opening manoeuvre is 15 seconds, for a
slowing down time of 3 seconds, the “normal speed time” must be set
to 12 seconds.
Normal closing speed
time [norM. cLS. SPEED]
Between 1 second and 2
minutes
15 s
Slowing down speed
[SLow SPEED]
0 - No slowing down
1 - Slowing level 1 (1/2)
2 - Slowing level 2 (1/3)
3 - slowing level 3 (1/4)
3
0 - Normal speed
1 - Average speed
2 - Slow speed
3 - very slow speed
Logic [LoGIc]: to select the motor operating mode and devices.
Automatic closure [tcA]
ON: Activates automatic
closure
off: deactivates automatic
closure
off
The gate closes automatically after the programmed time delay.
3 Step
[3 STEP]
ON: Activates the 3 step logic.
off
3 STEP = operation in semi-automatic mode (see “User's manual” pg. 3).
off: activates the 4 step logic.
4 stEP = operation in sequential mode
(see “User's manual” pg. 3).
Blocking impulses
[IbL oPEn]
ON: In opening mode only
off: None
off
Impulses during opening have no effect.
Photoelectric cell
operation
[Photoc. oPEn]
ON: In closing mode only.
off
In closing mode, the gate stops then reverses its movement.
In opening mode, cells are inactive.
off: in opening and closing
mode.
in closing mode, the gate stops and reverses its movement once
the cells are no longer obstructed.
in opening mode, the gate stops then continues its movement
once the cells are no longer obstructed.
Photoelectric cell test
[tESt Phot]
ON: Activates the cell autotest
function.
off: deactivates the cell
autotest function.
off
See the diagram for connection of the cells with autotest pg. 9 and 10.
Pre-warning
[PrEAL]
ON: With pre-warning
off
With pre-warning: the integrated flashing amber light comes on
approximately 3 seconds before motorisation starts.
off: Without pre-warning
Without pre-warning: the integrated flashing amber light comes
on when motorisation starts.
Sustained action
[hoLd-to-rUn]
ON: Operation with sustained
action activated.
off: operation with
impulse action, according to
3 or 4 step logic.
off
Operation in hold-to-run mode, only with a wired control: continuous
movement while the control button remains pressed.
Содержание Elixo 500