P19
Closing speed
1: slowest speed
at
10: fastest speed
Default value: 5
,IWKLVSDUDPHWHULVPRGL¿HGWKHLQVWDOOHUPXVWFKHFNWKDWWKHOLPLWDWLRQRIIRUFHV
complies with appendix A of the standard EN12 453 or install a safety edge.
P20
Opening speed
1: slowest speed
at
10: fastest speed
Default value: 5
P21
Closing slowdown zone 1: shortest slowdown zone
at
5: longest slowdown zone
Default value: 1
P22
Opening slowdown
zone
1: shortest slowdown zone
at
5: longest slowdown zone
Default value: 1
P25
Closing torque limitation 1: minimum torque
at
10: maximum torque
Adjusted at the end of self-learning
,IWKLVSDUDPHWHULVPRGL¿HGWKHLQVWDOOHUPXVWFKHFNWKDWWKHOLPLWDWLRQRIIRUFHV
complies with appendix A of the standard EN12 453 or install a safety edge.
If the torque is too low, there may be erratic obstacle detection.
If the torque is too high, the installation may not comply with the standard.
P26
Opening torque
limitation
1: minimum torque
at
10: maximum torque
Adjusted at the end of self-learning
P27
Closing slowdown
torque limitation
1: minimum torque
at
10: maximum torque
Adjusted at the end of self-learning
P28
Opening slowdown
torque limitation
1: minimum torque
at
10: maximum torque
Adjusted at the end of self-learning
P33
Obstacle detection
sensitivity
0: very low sensitivity
1: slightly sensitive
2: standard
3: very sensitive
,IWKLVSDUDPHWHULVPRGL¿HGWKHLQVWDOOHUPXVWFKHFNWKDWWKHOLPLWDWLRQRIIRUFHV
complies with appendix A of the standard EN12 453 or install a safety edge.
P37
Wired control inputs
0: complete cycle mode -
pedestrian cycle
1: opening mode - closing
0: terminal 9 input = pedestrian cycle, terminal 11 input = complete cycle
1: terminal 9 input = opening only, terminal 11 input = closing only
P40
Coupling speed when
closing
1: slowest speed
at
4: fastest speed
Default value: 2
,IWKLVSDUDPHWHULVPRGL¿HGWKHLQVWDOOHUPXVWFKHFNWKDWWKHOLPLWDWLRQRIIRUFHV
complies with appendix A of the standard EN12 453 or install a safety edge.
P41
Coupling speed when
opening
1: slowest speed
at
4: fastest speed
Default value: 2
Содержание Elixo 500 3S RTS
Страница 1: ...D811950_03_15 01 2015 ELIXO 500 3S RTS EN Installation instructions TR 0RQWDM N ODYX X FA AR...
Страница 2: ......
Страница 56: ...FAElixo 500 3S RTS 10 Copyright 2015 Somfy SAS All rights reserved H0 SET C1 STOP STOP 1 P07 20 19 3...
Страница 63: ...FA Elixo 500 3S RTS Copyright 2015 Somfy SAS All rights reserved 3 10 30 mA 2 kV 2400484 1 5 50...
Страница 64: ...FAElixo 500 3S RTS 2 Copyright 2015 Somfy SAS All rights reserved 1 www somfy com...
Страница 68: ...ARElixo 500 3S RTS Copyright 2015 Somfy SAS All rights reserved 19 7 7 SET SET A B Keygo RTS B A A A B 2s 1s...
Страница 77: ...AR Elixo 500 3S RTS 10 Copyright 2015 Somfy SAS All rights reserved H0 SET C1 STOP STOP 1 P07 20 19 3...
Страница 84: ...ARElixo 500 3S RTS Copyright 2015 Somfy SAS All rights reserved 3 10 30 2 2400484 1 5 50...
Страница 87: ......