EN
Elixo 500 3S RTS
20
Copyright © 2015 Somfy SAS. All rights reserved
DIAGNOSTICS
Operating code display
Code Description
Comments
C1
Awaiting command
C2
Gate opening
C3
Awaiting gate closure
Automatic closing time delay P02, P04 or P05 in progress.
C4
Gate closing
C6
Detection in progress for cell safety
Displayed during a movement request or during movement when detection is in progress on the safety input.
The display appears for as long as detection is in progress on the safety input.
C7
Detection in progress for safety edge safety
C8
Detection in progress for programmable safety
C9
Detection in progress for emergency stop safety
C12
5HLQMHFWLQJFXUUHQW
C13
Safety device autotest in progress
Displayed while the autotest is running on the safety devices.
C14
Permanent complete opening wire control input
Indicates that the complete opening wire control input is permanently activated (contact closed). Commands
coming from the radio remote controls are then disabled.
C15
Permanent pedestrian opening wire control input
Indicates that the pedestrian opening wire control input is permanently activated (contact closed). Commands
coming from the radio remote controls are then disabled.
C16
BUS cell programming refused
Check that the BUS cells (wiring, alignment, etc.) are operating correctly
Cc1
9.6 V power supply
Displayed during operation with 9.6 V backup battery
Cu1
24 V power supply
Displayed during operation with 24 V backup battery or solar supply
Programming code display
Code Description
Comments
H0
Awaiting setting
Pressing and holding the "
SET
" button for 2 seconds starts self-learning mode.
Hc1
Awaiting s 9.6 V power supply
Displayed during operation with 9.6 V backup battery
Hu1
Awaiting s 24 V power supply
Displayed during operation with 24 V backup battery or solar supply
H1
Awaiting start of self-learning
Pressing the "
OK
" button starts the self-learning cycle.
Pressing the "
+
" or "
-
" button allows the motor to be controlled in forced operation mode.
H2
Self-learning mode - opening
H4
Self-learning mode - closing
F0
Awaiting remote control memorisation for
operation in complete opening mode
Pressing a button on the remote control allocates this button to the motor complete opening control.
Pressing "
PROG
" once more switches to "awaiting remote control memorisation for operation in pedestrian opening
mode:
F1
".
F1
Awaiting remote control memorisation for
operation in pedestrian opening mode
Pressing a button on the remote control allocates this button to the motor pedestrian opening control.
Pressing "
PROG
" once more switches to "awaiting remote lighting control memorisation:
F2
".
F2
Awaiting remote control memorisation for
remote lighting control
Pressing a button on the remote control allocates this button to the remote lighting control.
Pressing "
PROG
" once more switches to "awaiting auxiliary output control memorisation:
F3
".
F3
Awaiting remote control memorisation for
auxiliary output control
Pressing a button on the remote control allocates this button to the remote lighting control.
Pressing "
PROG
" once more switches to "awaiting remote control memorisation for operation in complete opening
mode:
F0
".
Fault and breakdown code display
Code Description
Comments
Solution?
E1
Cell safety autotest fault
The cell autotest is not satisfactory.
&KHFNWKDW3LVFRUUHFWO\FRQ¿JXUHG
Check the wiring of the cells.
E2
Programmable safety autotest fault
The programmable safety input autotest is
not satisfactory.
&KHFNWKDW3LVFRUUHFWO\FRQ¿JXUHG
Check the programmable safety input wiring.
E3
Defective safety edge autotest
The safety edge autotest is not satisfactory.
&KHFNWKDW3LVFRUUHFWO\FRQ¿JXUHG
Check the safety edge wiring.
E4
Obstacle detection when opening
E5
Obstacle detection when closing
E6
Cell safety fault
Detection in progress on safety input for
longer than 3 minutes.
Check that no obstacles are causing the cells or safety edge to detect.
&KHFNWKDW33RU3LVFRUUHFWO\FRQ¿JXUHGLQUHODWLRQWRWKH
device connected to the safety input.
Check the safety device wiring.
Check that the photoelectric cells are correctly aligned.
E7
Safety edge safety fault
E8
Programmable safety fault
E10
Motor short circuit protection
Check the motor wiring.
E11
24V power supply short protection
Short circuit protection for input/outputs:
product and additional devices connected to
terminals 21 to 26 (orange light, photoelectric
cells (except BUS), code keypad, safety
edge) not operating
Check the wiring, then disconnect the power supply for 10 seconds.
N.B.: maximum accessories consumption = 1.2 A
E12
Hardware fault
The hardware auto tests are not satisfactory Repeat an order. If the fault persists, contact Somfy.
E13
Accessories power supply fault
The accessories power supply cuts
out following an overload (excessive
consumption)
N.B.: maximum accessories consumption = 1.2 A
Check the consumption of the connected accessories.
E15
Fault when the motor supplied by the
EDFNXSEDWWHU\LV¿UVWVZLWFKHGRQ
Disconnect the backup battery and connect the motor to the mains to switch it
RQIRUWKH¿UVWWLPH
For all other error codes or faults, please contact Somfy.
Содержание Elixo 500 3S RTS
Страница 1: ...D811950_03_15 01 2015 ELIXO 500 3S RTS EN Installation instructions TR 0RQWDM N ODYX X FA AR...
Страница 2: ......
Страница 56: ...FAElixo 500 3S RTS 10 Copyright 2015 Somfy SAS All rights reserved H0 SET C1 STOP STOP 1 P07 20 19 3...
Страница 63: ...FA Elixo 500 3S RTS Copyright 2015 Somfy SAS All rights reserved 3 10 30 mA 2 kV 2400484 1 5 50...
Страница 64: ...FAElixo 500 3S RTS 2 Copyright 2015 Somfy SAS All rights reserved 1 www somfy com...
Страница 68: ...ARElixo 500 3S RTS Copyright 2015 Somfy SAS All rights reserved 19 7 7 SET SET A B Keygo RTS B A A A B 2s 1s...
Страница 77: ...AR Elixo 500 3S RTS 10 Copyright 2015 Somfy SAS All rights reserved H0 SET C1 STOP STOP 1 P07 20 19 3...
Страница 84: ...ARElixo 500 3S RTS Copyright 2015 Somfy SAS All rights reserved 3 10 30 2 2400484 1 5 50...
Страница 87: ......