10
Copyright © 2008 Somfy SAS. All rights reserved.
EN
Elixo 500 230 V
Press the PROG button on the motorisation control unit for more than 7 seconds. The indicator light flashes to indicate that all
remote controls have been cleared.
The auto-diagnostic LEDS, located on the control unit terminal, control the
operation of the motor and its additional devices.
DL2
START - lights up on the START command
DL3
STOP - goes out on the STOP command
DL4
PHOT - goes out if the photoelectric cells are not aligned or if they are
obstructed
DL5
SWO - goes out on the opening end limit command
DL6
SWC - goes out on the closing end limit command
motor
Power supply
230 V 50Hz
Motor power supply
230 V AC
Motor revolutions
1400 rpm
Power consumption
290 W
Maximum consumed current
1.5 A (230 V) - 3 A (110 V)
Capacitor
10 μF (230 V) - 40 μF (110 V)
Thermal protection
110°C
Insulation category
F
Reduction ratio
1/30
Revolutions at output
48 rpm
Pinion
4 mm module (14 teeth)
Gate speed
8.5 m/min
Maximum weight of the gate
500 kg
Maximum torque
20 Nm
Lubrication
Permanent grease
Manual manoeuvres
Mechanical release with handle
Number of cycles/day
100
Obstacle detection
Friction clutch
Control unit
Integrated
Operating temperature
-15 °C to +60 °C
Index protection rating
IP24
Weight
15 kg
Dimensions
see “General motor size” pg. 3
ElECtroNiCs
Accessories power supply
24 V (0.2 A maximum absorbed)
Automatic closure time
between 0 and 90 seconds
Operating time
between 0 and 120 seconds
Pedestrian opening time
7 seconds (fixed)
Reversal pause
1 second approximately
Flashing orange light connection
230 V maximum 15 W
Fuses
250 V T 0.62 A and T 1 A
Built in radio receiver
RTS
Number of storable remote controls
36
RTS remote control frequency
433.42 Mhz
Aerial resistance
50 Ohm (RG58)
ClEariNG all rEmotE CoNtrols
diaGNostiCs
tEChNiCal sPECifiCatioNs
Содержание Elixo 500 230 V
Страница 43: ......