Copyright © 2008 Somfy SAS. All rights reserved.
9
EN
Elixo 500 230 V
Wired keyswitch
7 s
A
A
B
B
24V
IIß RC
0V
19
20
ST
OP
NC
PHOT
NC
ST
AR
T
CO
M
NO
18
7
NC
SW
O
SW
C
NC
PED
8
9
11
12
14
15
13
10
16
17
Potentiometers: to modify the automatic closing time and the motor run time.
TCA:
Automatic closure time
Between 0 and 90
seconds
Setting the time delay for automatic closing
(if DIP1 is ON).
TW:
Motor run time
Between 0 and 120
seconds
The motor run time should be slightly longer than
the actual closing time of the gate.
DIP switch: to select the operating mode for the motor and its additional devices.
DIP 1:
Automatic closure
ON: Activates automatic
closure
off: deactivates
automatic closure
The gate closes automatically after the
programmed time delay (TCA).
DIP 2:
Operation of the
photoelectric cells
ON: In closing mode only. In closing mode, the gate stops then reverses its
movement.
In opening mode, cells are inactive.
off: in opening and
closing mode.
in closing mode, the gate stops and reverses
its movement once the cells are no longer
obstructed.
in opening mode, the gate stops then
continues its movement once the cells are no
longer obstructed.
DIP 3:
Blocking impulses
ON: In opening mode only
off: None
Impulses during opening have no effect.
DIP 4:
3 Step/4 Step
ON: Activates the 3 step
logic.
3 STEP = operation in semi-automatic mode
(see “User's manual” pg. 2).
off: activates the 4
step logic.
4 stEP = operation in sequential mode
(see “User's manual” pg. 2).
DIP 5
DIP 6
DIP 5 and 6 are not used and have no effect on the operation of the motor
and its additional devices.
DIP 7
Pedestrian opening
ON: Activates the
pedestrian opening.
off: deactivates the
pedestrian opening.
Pressing the remote control briefly partially opens
the gate and pressing and holding the remote
control fully opens the gate.
Fixed opening time: 7 seconds.
ParamEtEr sEttiNG
ON
OFF
DIP 8
TCA
+
+
-
-
TW
DIP 7
DIP 6
DIP 5
DIP 4
DIP 3
DIP 2
DIP 1
Содержание Elixo 500 230 V