6. CONNECTING ADDITIONAL DEVICES
Danger
Switch off the electrical supply to the motor before performing any
operation on the additional devices.
6.1. General wiring diagram - Fig. 10
Termi-
nal
Definition
Description
P
ow
er supply
Live
Single-phase power supply
220-230V 50/60 Hz
Neutral
Earth
Motor
4
M (brown)
Motor connection
5
B (blue)
6
N (black)
Aux
7
LIGHT 230V
230 V flashing orange light, max.
40 W
8
9
Dry contact
(max. 24V 0.5A)
AUX3 configurable output
See "7.2. List of settings"
10
End
limits
12
E
Common
13
SWC
Closing end limit (NC)
14
SWO
Opening end limit (NC)
Accessories
pow
er supply
15
0 V
Accessories power supply output
16
24 V
17
Test
Power supply output for safety
mechanisms tested (photoelectric
cells and safety edge transmitter)
Output active only when moving
Commands
18
COM
START and PED inputs common
19
START
TOTAL control input (NO)
20
PED
PEDESTRIAN control input (NO)
21
COM
OPEN and CLOSE inputs common
22
OPEN
OPENING control input only (NO)
23
CLOSE
CLOSING control input only (NO)
Safety devices
24
COM
STOP, PHOT OPEN and PHOT CLOSE
inputs common
25
Emergency stop
26
PHOT OPEN
Dry contact for cells active when
opening (NC)
27
Not used
28
PHOT CLOSE
Dry contact for cells active when
closing (NC)
29
Not used
30
COM
BAR input common
31
BAR
Dry contact for safety edge active
when opening and closing
32
Not used
Y
Conductor
Antenna
#
Braid
6.2. Description of the various additional devices
6.2.1. Photoelectric cells
Without autotest
Active when opening - Fig. 16
Active when closing - Fig. 17
With autotest
Active when opening - Fig. 18
Active when closing - Fig. 19
6.2.2. Orange light - Fig. 20