EN
Soliris io
18
Copyright
©
2019-2021 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
1] Switch off the mains power supply.
2] Unscrew the front panel (N) of the mounting bracket to access
the terminal block.
Attention
Never remove the cover located under the anemometer.
3] Unscrew the
left-hand
metal tab (O).
4] Drill a hole in the
left-hand
sealant pad (P).
Attention
• Never remove the sealant pad.
• The hole drilled in the pad must not exceed the diameter of the
cable in order to maintain tightness.
5] Feed the cable (B) through the sealant pad.
6] Connect the power supply cable (B) to the sensor using the
left-
hand terminal block marked "230V"
(Q).
Attention
The cable must be stripped to 6 mm.
7] Screw in the metal tab (O): the cable must be fed under the tab.
Attention
The cable sheath must exceed the tab by at least 2 mm.
͉
To add the wiring for a rain sensor (e.g. Ondeis), go to section
2.3.2.
8] Check the presence, good condition and the position of the seal
(R) before fitting the cover.
9] Screw the front panel (N) of the mounting bracket back on.
Attention
Tighten the screws completely to maintain the tightness of the
mounting bracket.
To complete the installation, go to section
2.4.
OFF
1
]
N
2
]
O
3
]
P
4
]
6]
B
Q
5]
B
O
7]
230V
≥2mm
RAIN
≥2mm
8]
R
N
9]