46
Heavy flow from
overflow pipe.
1. Excessive foaming
1. Add a de-foamer.
2. Blockage of return line.
2. Check individual cleanouts to locate
blockage.
3. Improper Return water
flow.
3. Readjust throttling valves.
Excessively wet
pulp discharge
from Hydra-
Extractor®.
1. Blockage of screen.
1. Clean the Hydra-Extractor screen. Refer
to Hydra-Extractor Maintenance Section of
the manual.
2. Worn screw and
brush.
2. Remove and replace. Refer to Hydra-
Extractor Maintenance Section of this
manual.