32
CLEANING INSTRUCTIONS
After feeding waste to the SOMAT
®
System has been completed for the day, the equipment
should be thoroughly cleaned. A regular cleaning program will eliminate odors, costly
maintenance and unsatisfactory operation.
CLEANING THE PULPER:
With the system properly shut down, in accordance with the System "Shutdown Procedures",
perform the following:
1.
Clean the Junk Box of non-pulpable material.
2.
CAUTION BROKEN GLASS MAY BE PRESENT IN
THE PULPER
3.
Wash the interior of the pulper shell with a hot
water hose, suitable brush, detergent and deodorant or
other cleaning solution. Exercise care in cleaning the
underside of the upper shell flange. Wipe down the
equipment exterior.
4.Leave lid open (if allowed) to let machine air out and
reduce odors.
CLEANING THE HYDRA-EXTRACTOR
®
:
With a hot water high-pressure hose, wash down screens and interior walls of Hydra-Extractor
®
housing. If necessary, a long-handled brush can be used.
Long Term Shut Down Procedure -
If the Pulper is to remain idle for a relatively long period
(three weeks or more), perform the daily cleaning procedure and then circulate a solution of a
cleaning and disinfecting agent through the lines followed by a secondary shutdown
procedure to combat bacteria growth and odor.
Underside of Flange
Содержание SPC-50S
Страница 12: ...12 Installation ...
Страница 15: ...15 OPTIONAL EQUIPMENT 1 Remote Push Button Station 2 Trough Magnet Hardware 3 Tray Feed Hood 1 2 3 ...
Страница 23: ...23 Start Up ...
Страница 26: ...26 Operation ...
Страница 31: ...31 CLEANING YOUR SYSTEM ...
Страница 34: ...34 MAINTENANCE ...
Страница 43: ...43 TROUBLESHOOTING ...
Страница 47: ...47 Display Module Instructions ...
Страница 52: ...52 165 Independence Ct Lancaster Pa 17601 Ph 800 237 6628 service somatcompany com ...