111710-901-08/07
RSM 400
20 / 23
5
Getting Started
5.1
Set Up via SOMAG Mount Control App
Information regarding the usage of SOMAG Mount Control App can be found in the following document:
‘110080
-901-
08/XX SOMAG Mount Control App Manual’.
•
The RSM 400 gain factor (see
chapter ‘Settings 1’ in document ‘110080
-901-08/XX SOMAG
Mount Control App Manual’) is set by default to a relatively low level. Once the unit and the
payload are properly installed, the value can be increased to ensure the best performance of
the Stabilization Mount.
5.2
Power Up / Initialization
It is necessary to check the cabling of the different components before switching on the device. All cables
need to be arranged and connected according to chapter 4.2.2.
•
The RSM 400 moving area must not be obstructed by any other components, as otherwise the
device or the payload might receive irreparable damage.
•
The Mount is switched ON as soon as the power supply is connected. Make sure that the de-
vice is properly secured / bolted to a stable and even surface before power is applied.
•
It is recommended to run the Mount without any payload for the first trials.
•
During the initialization phase, avoid applying unnecessary force onto the payload and the
Mount, as it may disrupt the electronic test phase (ETP) and thus reduce stabilization perfor-
mance.
•
A restart of the Mount recalibrates the device properly.
The following sequence will start once power is applied:
•
The internal controller of the Mount starts up.
Mechanical Test Phase (MTP) / 120 s:
•
During the
MTP
the Mount moves down to its lowest position in roll and pitch. This process can take up to
120 s. It is dependent on the position of all axes at power on. It then moves back to its highest position and
afterwards to its working-position with 0° for Roll, Pitch.
Range Test Phase (RTP) / 5-15 s:
•
The Mount fulfills a short movement in all axes to ensure functionality of them.
Electronic Test Phase (ETP) / 20 s:
•
If necessary, the device runs the electronic test phase (ETP) to check proper functionality of all sensors
and electronic components.
When the MTP, RTP and ETP are completed, the RSM 400 turns into its preset default mode (can be set up with
the SOMAG Mount Control App / see chapter 5.1).
•
In ‘STAB’ mode, the Mount actively stabilizes the payload to ensure a level position.
•
In ‘MAN’ mode, the automatic gy
ro stabilization is turned off.