Troubleshooting
Problem
Solution
Glass gets dirty quickly
. Check moisture of firewood
. Increase burn intensity by opening the combustion
air intake regulator slightly
. Open flue damper
(where applicable)
Excessive draft
. Check if the combustion air intake regulator is
open. If so, close it.
. Contact the installer
Weak draught, causing
smoke to be expelled
into the room
. Check that the flue is clear of obstructions
. Clean the flue
. There may be exceptional weather conditions
Weak fire
. Check moisture of firewood and opening of the
combustion air intake regulator
. Check entry of air into the room
Ventilation stopped
working
. Check possible obstruction of ventilators
. Check and/or reconnect power supply
. The stove may not be hot enough to make the
ventilators switch on
Ventilation working but
flow is weak
. Clean all dust, ash or other residue that may have
accumulated in the ventilator grilles
Problems associated
with the weather
. Contact the installer
End of Life
* Around 90% of the materials used in the manufacture of these units is
recyclable, thus helping to reduce environmental impact and contributing to
the sustainable development of the planet;
* End-of-life units should be taken to licensed waste operators. We advise
you to contact your local council for collection.
Sustainability
* Solzaima designs solutions and equipment "moved" by biomass as their
primary energy source. This is our contribution for the sustainability of our
planet
– an economically viable and environmentally-friendly alternative,
following environmental best management practices to ensure an efficient
carbon cycle management.
* Solzaima cares about being up to date with and assessing the existing
forest area while efficiently responding to energetic demands, with a
constant watch on biodiversity and natural wealth, critical aspects to the
quality of life in our planet.
21
22