MBUS-PS - User manual
1.6 Safety guidelines
Observe the recognized rules of technology and the legal requirements, standards and norms, and other
recommendations.
Study the instructions for the extinction of fire in electrical installations.
The power supply must be switched off before replacing components and modules.
If the contacts are deformed, the affected module or connector must be replaced, as the function is not guar-
anteed in the long term.
The components are not resistant to substances that have creeping and insulating properties. These include
e.g. aerosols, silicones, triglycerides (ingredient of some hand creams). If the presence of these substances in
the vicinity of the components cannot be excluded, additional measures must be taken:
• Install the components in an appropriate casing.
• Handle components with clean tools and materials only.
Only use a soft, wet cloth for cleaning. Soapy water is allowed. Pay attention to ESD.
Do not use solvents like alcohol, acetone etc. for cleaning.
Do not use a contact spray, because in an extreme case the function of the contact point is impaired
and may lead to short circuits.
Assemblies, especially OEM modules, are designed for installation in electronic housings. Do not touch
the assembly when it is live. In each case, the valid standards and directives applicable to the construction
of control cabinets must be observed.
The components are populated with electronic parts which can be destroyed by an electrostatic discharge.
When handling the components, ensure that everything in the vicinity is well earthed (personnel, work-
place and packaging). Do not touch electrically conductive components, e.g. data contacts.
1.7 Scope
This documentation describes the device manufactured by solvimus GmbH, Ilmenau, and stated on the title
page.
1.8 Abbreviations
Abbreviation
Meaning
2G
Mobile radio standard, synonym for GSM or GPRS
3G
Mobile radio standard, synonym for UMTS
4G
Mobile radio standard, synonym for LTE
ACK
Acknowledge
AES
Advanced Encryption Standard
AFL
Authentication and Fragmentation Layer
AI
Analog Input
ANSI
American National Standards Institute
AO
Analog Output
APN
Access Point Name
ASCII
American Standard Code for Information Interchange
ASHRAE
American Society of Heating, Refrigerating and Air-Conditioning Engineers
BACnet
Building Automation and Control networks
BBMD
BACnet Broadcast Management Device
BCD
Binary-coded decimal numbers
BDT
Broadcast Distribution Table
BMS
Building Management System
CA
Certification Authority
CHAP
Challenge Handshake Authentication Protocol
CI
Control Information
CLI
Command line interface
COSEM
COmpanion Specification for Energy Metering
CPU
Central processing unit
CRC
Cyclic redundancy check
CSV
Character-Separated Values
Continued on next page
Page 6/18
UG_EN_MBUS-PS.pdf
Version: 1.4
Released
Frank Richter, 6 December 2022
© solvimus GmbH