background image

MBUS-PS - User manual

Table 2 –

Continued from previous page

Abbreviation

Meaning

CTS

Clear to send

D0

D0 interface (optical interface, IEC 62056-21)

DDC

Direct Digital Control

DHCP

Dynamic Host Configuration Protocol

DI

Digital Input, digital input terminal

DIF

Data information field

DIFE

Data information field extensions

DIN

Deutsches Institut für Normung, German Institute for Standardization

DLDE

Direct Local Data Exchange (EN 62056-21, IEC 1107)

DLDERS

DLDE communication via RS-232 or RS-485

DLMS

Device Language Message Specification

DNS

Domain Name System

DO

Digital Output, digital output terminal

EEG

German Renewable Energy Sources Act

EIA/TIA

Electronic Industries Alliance/Telecommunications Industry Association

ELL

Extended Link Layer

EMC

Electromagnetic compatibility

EN

European norm

ESD

Electrostatic Discharge

FCB

Frame Count Bit

FCV

Frame Count Valid Bit

FNN

Forum Netztechnik/Netzbetrieb, subgroup of VDE

FSK

Frequency Shift Keying

FTP

File Transfer Protocol

FTPS

FTP via TLS

GB

Gigabyte

GMT

Greenwich Mean Time

GPRS

General Packet Radio Service

GSM

Global System for Mobile Communications

HCA

Heat cost allocator

HTTP

Hypertext Transfer Protocol

HTTPS

Hypertext Transfer Protocol Secure

I2C

Inter-Integrated Circuit

I/O

Input/Output

ICMP

Internet Control Message Protocol

ID

Identification, Identifier, unique marking

IEC

International Electrotechnical Commission

IEEE

Institute of Electrical and Electronics Engineers

IoT

Internet of Things

IP

Internet Protocol or IP address

ISO

International Organization for Standardization

JSON

JavaScript Object Notation

LAN

Local area network

LED

Light-Emitting Diode

LSB

Least significant byte

LSW

Least significant word

LTE

Long Term Evolution

M2M

Machine-to-Machine

M-Bus

Meter-Bus (EN 13757, part 2, 3 and 7)

MAC

Medium Access Control or MAC-Adresse

MB

Megabyte

MCR

Multi Channel Reporting

MDM

Meter Data Management

MEI

Modbus Encapsulated Interface

MHz

Megahertz

MQTT

Message Queuing Telemetry Transport

MSB

Most Significant Byte

MSW

Most Significant Word

MUC

Multi Utility Communication, MUC controller

NB-IoT

Narrow Band Internet of Things

OBIS

Object Identification System

OEM

Original Equipment Manufacturer

OMS

Open Metering System

PAP

Password Authentication Protocol

PEM

Privacy Enhanced Mail

PIN

Personal Identification Number

PKI

Public Key Infrastructure

PLC

Programmable Logic Controller

PPP

Point-to-Point Protocol

PPPoE

Point-to-Point Protocol over Ethernet

PUK

Personal Unblocking Key

Continued on next page

Frank Richter, 6 December 2022
© solvimus GmbH

Version: 1.4

Released

Page 7/18

UG_EN_MBUS-PS.pdf

Содержание MBUS-PS125

Страница 1: ...he M Bus Version 1 4 Date 6 December 2022 Authors Remo Reichel Frank Richter solvimus GmbH Ratsteichstr 5 98693 Ilmenau Germany solvimus GmbH Ratsteichstr 5 98693 Ilmenau Germany Telephone 49 3677 761...

Страница 2: ...MBUS PS User manual Page intentionally left blank Page 2 18 UG_EN_MBUS PS pdf Version 1 4 Released Frank Richter 6 December 2022 solvimus GmbH...

Страница 3: ...lines 6 1 7 Scope 6 1 8 Abbreviations 6 2 Introducing the device 9 2 1 General information 9 2 2 Delivery variants and scope of delivery 9 2 3 Connectors 9 2 4 Status LEDs 11 2 5 First steps 11 2 5 1...

Страница 4: ...on is intended exclusively for qualified electricians or persons instructed by these They must all have good knowledge in the following areas Applicable standards Use of electronic devices 1 2 4 Inten...

Страница 5: ...ther information References to additional literature manuals data sheets and internet pages 1 4 Font conventions Names of paths and files are marked in italics According to the system the notation is...

Страница 6: ...struction of control cabinets must be observed The components are populated with electronic parts which can be destroyed by an electrostatic discharge When handling the components ensure that everythi...

Страница 7: ...Protocol Secure I2C Inter Integrated Circuit I O Input Output ICMP Internet Control Message Protocol ID Identification Identifier unique marking IEC International Electrotechnical Commission IEEE Inst...

Страница 8: ...hort Range Device SSH Secure Shell SSL Secure Sockets Layer TCP Transmission Control Protocol THT Through Hole Technology TLS Transport Layer Security U Unit width of the housing 1 U 18 mm UART Univer...

Страница 9: ...thus be mapped in a PC software This enables simple meter reading and meter configuration using a PC In automation also a typical PLC can access meters via MBUS PS provided the PLC supports the protoc...

Страница 10: ...line for receiving data from the PC according to MBUS PS6 TX signal line for transmitting data on the M Bus ANSI EIA TIA 232 F 1997 MBUS PS32 GND TX signal line for transmitting data to the PC screw t...

Страница 11: ...tive load on the M Bus red blinking Overload of the M Bus master TX yellow Reception of data from the master PC and transmission to the M Bus slaves RX green Reception of data from the M Bus slaves an...

Страница 12: ...nsmits telegrams by modulating the current through the bus This is shown schematically in the following figure values of current and voltage may deviate Figure 4 Signalling on the M Bus The M Bus foll...

Страница 13: ...eter use of the SND_UD for selecting the meter via the application layer then selected meter can be addressed via special address 0xFD Standard load Defined idle current that a meter may draw from the...

Страница 14: ...ust be crossed between the PC and MBUS PS if need be If errors could not be eliminated please contact our customer support E Mail support solvimus de Phone 49 3677 7613065 The reception LED remains of...

Страница 15: ...te to the number of connected slaves If errors could not be eliminated please contact our customer support E Mail support solvimus de Phone 49 3677 7613065 The collision LED lights up when sending res...

Страница 16: ...e polarity protected M Bus overvoltage protection transients protection class III IEC 61140 Peak inrush current approx 3 A Meter interfaces The devices have an M Bus meter interface pin assignment see...

Страница 17: ...PS32 MBUS PS125 MBUS PS250 MBUS PS500 screw terminals 1 5 mm2 tightening torque 0 5 0 6 Nm MBUS PS20 MBUS PS80 D Sub male plug 9 contacts No handshake Galvanic isolation The RS 232 communication inter...

Страница 18: ...der number of the solvimus GmbH 1 PHOENIX CONTACT STEP PS 1AC 24DC 0 5 103501 3 PHOENIX CONTACT STEP PS 1AC 24DC 1 75 103960 Table 10 External power supplies The usage of accessories not recommended i...

Отзывы: