background image

 

 

 

8

 / 

46

 

 

 

1.2.3 Maintenance and replacement 

 

 

• Only qualified electricians are allowed to perform the maintenance, 

inspection, and component replacement of the machine. 

• Please contact the distributor or manufacturer for maintenance. 
• In order to avoid irrelevant personnel from entering the maintenance 

area during maintenance, temporary warning signs must be placed 

to warn non-professionals to enter or use fence for isolation. 

• Before carrying out any maintenance operations, all input power to 

the machine must be disconnected first, and wait for at least 5 

minutes until the internal parts of the machine are fully discharged. 

• Please follow the electrostatic protection norms, and take correct 

protective measures because there are mostly electrostatic 

sensitive circuits and devices in the machine. 

• Do not use parts and components not provided by our company 

during maintenance. 

• Restart the machine after eliminating the faults and problems which 

may affect the safety and performance of the machine. 

• Do not get close to or touch any charged metal conductor parts of 

the grid or running system, otherwise electric shock or fire may 

occur. Please do not ignore the warning icons and instructions with 
“electric shock”. 

 

1.2.4 What to do after scrapping 

 

 

• Do not dispose of the machine together with household waste. The 

user has the responsibility and obligation to send it to the designated 

organization for recycling and disposal.

 

 

 

 

 

 

 

 

Содержание S12 NA Series

Страница 1: ...1 46 User Manual Home Energy Storage System Soluna S12 NA Mar 2020 Revision A 0...

Страница 2: ...l contact Soluna immediately for advising and clarification The information included in this manual is accurate at the time of publication however with regards to the product design and technical spec...

Страница 3: ...4 1Turn on or turn off Soluna 32 4 2 How to operate LCD 33 4 2 1 Place of LCD 33 4 2 2 How to check the information of LCD screen 34 4 2 3 How to check the information of Status icon 34 4 2 4 How to...

Страница 4: ...ll not responsible for any consequence caused by any of the following events Damage caused by transportation The storage conditions do not meet the requirements specified in the manual resulting in da...

Страница 5: ...n this manual Sign Name Description Danger Serious physical injury or even death may occur if related requirements are not followed Warning Physical injury or damage to the devices may occur if relate...

Страница 6: ...und with proper technics before operation Do not open the surface cover of the machine unless authorized The electronic components inside the machine are electrostatic sensitive Do take proper anti el...

Страница 7: ...llation tools and take mechanical protection measures to protect personal safety such as wearing smashing shoes coverall and so on Only qualified electricians are allowed to install the machine Do not...

Страница 8: ...discharged Please follow the electrostatic protection norms and take correct protective measures because there are mostly electrostatic sensitive circuits and devices in the machine Do not use parts a...

Страница 9: ...the grid but also improves the household energy self consumption and saves the electricity cost Soluna integrated energy storage solve solution help users with achieving maximize the self use of gree...

Страница 10: ...10 46 2 3 Outline Dimensions Figure 2 1 outline dimension Width 750 mm Depth 565 mm Height 1335 mm Weight 300 kg...

Страница 11: ...11 46 2 4 Functional description 2 4 1 basic principle of Soluna S12 NA Figure2 2 basic principle of Soluna S12 NA...

Страница 12: ...remaining power and grid sell power is adjustable Mode 7 UPS Function can ensure important loads still powered in case grid suddenly fail down 2 5 Technical data 2 5 1 Technical data of System Specifi...

Страница 13: ...51 2 Voltage range V 42 58 42 58 42 58 42 58 Max charge current A 120A 135A 150 150 Max discharge current A 120A 135A 150 150 DOD 80 80 80 80 Cycle life 6000 6000 6000 6000 Others Protective class Cla...

Страница 14: ...nect Contactor Fuse BMS Power consumption 3W work 100mW sleep Monitoring parameters System Voltage System Current Cell Voltage Cell temperature Communication CAN System Configuration Module parallel 1...

Страница 15: ...15 46 2 6 Appearance Figure 2 3 Appearance Number Name Remark Soluna brand LCD panel...

Страница 16: ...16 46 Figure 2 4 Appearance Number Name Remark FAN outlet FAN outlet Emergency Stop Incoming wire port Label Product S N...

Страница 17: ...17 46 Figure2 5 Appearance Number Name Remark Door lock of system Door Key...

Страница 18: ...18 46 3 Installation 3 1 Installation tools...

Страница 19: ...llation spacing around the machine during installation Position Min spacing Remark Side spacing 100cm Back spacing 10cm It needs to be installed against the wall Note For detailed requirements about t...

Страница 20: ...tact the supplier timely Store the idled machine in its original package and take anti moisture and anti dust measures after taking the machine out of the box check the following items Item Name Qty p...

Страница 21: ...to 40 C the relative temperature should range from 4 to 100 Reserve enough installation spacing between the front rear left and right top and wall of the energy storage integrated machine cabinet to...

Страница 22: ...22 46 Step2 The system is installed against the wall Figure 3 2 installation place Number Name Remark Wall Soluna System Expansion Screw Fixed Bracket Ground...

Страница 23: ...23 46 Step3 Open the door of Soluna system and open the case of battery module Figure 3 3 System case Figure 3 4 Battery unit Number Name Remark System case Case of Battery module...

Страница 24: ...n of adding RJ45 terminal User can find the RJ45 terminal in the accessories Please find the following picture for RJ45 terminal for details Figure 3 5 RJ45 terminal Number Name Remark Remote wire Bat...

Страница 25: ...25 46 Step 5 Fixed battery module and Close the door of Soluna system Figure 3 6 Fixed battery module Number Name Remark M6 12 screw Fixed bracket...

Страница 26: ...26 46 Step6 external circuit connection GRID LOAD GEN PV 1 Port of external circuit Figure3 7 external circuit port Number Name Remark Load Port Grid Port Gen Port Others Port PV1 Port PV2 Port...

Страница 27: ...una then open the Distribution box of Soluna Please find the following picture for the position of distribution box of Soluna Figure 3 8 Place of distribution box of Soluna Number Name Remark Distribu...

Страница 28: ...ol signal port of limit power 1 3 Limit2 1 control signal port of limit power 2 4 Limit2 2 control signal port of limit power 2 5 GEN 1 control signal port of GEN 6 GEN 2 control signal port of GEN 7...

Страница 29: ...6 N m Ensure that the maximum open circuit voltage of each PV string is not higher than the maximum input voltage of the energy storage integrated machine under any circumstances It is forbidden to co...

Страница 30: ...the mains and load cables Terminal crimping torque 3 6 4 6 N m Note Before connecting the AC power grid cable to the energy storage integrated machine the lightning protection and short circuit protec...

Страница 31: ...p7 Electrical connection Figure3 11 Electrical connection Number Name Remark A PV string B PV side breaker DC1000V 25A 4P C Soluna S12 NA D AC side breaker AC400V 80A 2P E Power meter F Grid G Load H...

Страница 32: ...tch of Load Grid Battery Remote Turn off Open the door and turn off all the switch of Load Grid Battery Remote Please check the following picture for the position of switch Figure4 1 T urn on Turn off...

Страница 33: ...33 46 4 2 How to operate LCD 4 2 1 Place of LCD Figure 4 2 Place of LCD Number Name Remark LCD panel Note The LCD is touch screen user can touch the screen to see the information of system...

Страница 34: ...mation Battery Capacity Click each icon will see the relevant information Please find the following picture for the interface of LCD screen Figure 4 3 LCD Screen 4 2 3 How to check the information of...

Страница 35: ...35 46 Figure 4 5 PV information Figure 4 6 Load information...

Страница 36: ...36 46 Figure 4 7 Grid information Figure 4 8 Battery information...

Страница 37: ...ters of Soluna system a User find the following interface after clicking the icon of Setting Figure 4 9 Setting iron information User can find the following interface after clicking the icon of Power...

Страница 38: ...38 46 Figure 4 11 Charging setting 1 Figure 4 12 Charging setting 2 Figure 4 13 Charging setting 3...

Страница 39: ...4 14 Discharging setting 1 Figure 4 15 Discharging setting 2 c User can find the following interface after clicking the icon of Languages Figure 4 16 Language selection Remark There are 3 kinds of lan...

Страница 40: ...he following interface after clicking the icon of Reset advanced Setting User need to enter password if the user wants to restore the parameters of Soluna system Remark Soluna will provide the passwor...

Страница 41: ...the information of Data iron User can find the following interface after clicking the icon of Data Figure 4 20 Data iron a User can find the following interface after clicking the icon of Solar genera...

Страница 42: ...Statistics of selling back to the grid C User can find the following interface after clicking the icon of Equivalent tree Planting Figure 4 23 Equivalent tree planting d User can find the following i...

Страница 43: ...ction information 4 2 7 How to Check the fault information User can find the fault information after click the fault icon Remark User will find an icon blinking in the upper right corner of the LCD pa...

Страница 44: ...blades rotation at high speed 5 3 Fault handling If Soluna system has any failure information shown in the table below and it has not been eliminated after restart Please contact us or local distribu...

Страница 45: ...age 42 AC Line W U low voltage 43 AC Line W V over voltage 44 AC Line W V low voltage 45 AC Line U V over voltage 46 AC Line U V low voltage 47 AC Over frequency 48 AC Low frequency 49 Phase U grid cu...

Страница 46: ...battery when the PV power off grid power outage and battery power shortage If the user who want use the diesel generator function please contact to us following the engineers instruction to operate 7...

Отзывы: