Cleaning and maintenance
42
5.8.3
Starter
y
Replace faulty starters immediately.
You can recognise a faulty starter by the blackened ends of the (UV) low
pressure lamps or when the (UV) low pressure lamps can no longer be
started.
Operating a (UV) low pressure lamp with a faulty starter significantly shortens
its service life. The (UV) low pressure lamp loses power and may begin to
flicker under certain circumstances.
The starters are located in either one of the two lamp sockets or become
visible when the (UV) low pressure lamps are removed.
–
Turn 90° and carefully remove from the socket.
5.8.4
High pressure lamps and filter panels
UV high pressure lamps are used in facial tanners.
DANGER!
Fire hazard due to overheated lamps!
Non-approved high pressure lamps can explode. Hot lamp
components can set other parts on fire. People can be killed
or severely injured due to smoke inhalation and fire.
–
Only fit the high pressure lamps specified by the manu-
facturer.
–
Clean the inside of the device regularly. Dust particles
are flammable!
–
Release the clamping holder.
–
Lift the filter panel, pull it out of the guide and remove it.
Содержание XL-75xtra DYNAMIC POWER
Страница 2: ...XL 75XTRA Series GEBRAUCHSANWEISUNG OPERATING INSTRUCTIONS Norm 0 3 OPTIMIZED PERFORMANCE EN...
Страница 26: ...Bedienung 05 2011 1007430 01 Gebrauchsanweisung 25 4 5 bersicht Bedienung...
Страница 77: ...Index 76...
Страница 102: ...Operation 05 2011 1007430 01 Operating instructions 25 4 5 Operating overview...
Страница 151: ...Index 74...