Example 2 - How to
connect
5000VA
model to PV panels with the following
parameters?
•
P
max
: 250W
•
V
oc
: 36.6V
•
I
sc
: 8.75A
•
V
mp
: 30.96V
•
I
mp
: 8.07A
(1)
The max. PV input power for 5000VA model is 3750W,
3750W / 250W = 15
⇒
min. 15 PV panels shall be connected.
(2)
Best Operating Voltage Range is 70~120V,
120V/30.96V = 3.87
⇒
max. number of PV panel in series is 3.
(3)
Taking (1)~(2) into consideration, the optimized configuration is 3 PV panels
in series as a string, and 5 strings in parallel (as shown below).
(4)
Check again the V
oc
and I
sc
of PV string,
V
oc
of string is 3 x 36.6V = 109.8V < 150V (Max. PV Input Voltage)
⇒
OK
I
sc
of string is 5 x 8.75A = 43.75A < 50A (Max. PV Input Current)
⇒
OK