![Sollae Systems CSE-H25 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/sollae-systems/cse-h25/cse-h25_user-manual_1316257026.webp)
CSE-H25 User
’
s Manual Ver. 1.2
Sollae Systems Co., Ltd.
- 25 -
http://www.sollae.co.kr
Figure 4-5 Checking System Uptime
Serial Ports I/O data capture
User can monitor the input / output data of CSE-H25‟s serial ports with the “sd”
command. The way of using this command is like below.
“sd [SPACE] [# of Serial Port] [SPACE] [Interval]”
The value of [# of Serial Port] should be COM1. [Interval] means duration of capturing
and printing data on your screen and its unit is mille second (ms).
For example, if you want to capture the data in every second, the value of [Interval]
should be 100.
Figure 4-6 Capturing Data on the RS232 Port
Termination of TCP connection
Using “sc” command, users can terminate established TCP connection. The way of using
this command is like below.
“sc [SPACE] [Name of Session] [SPACE] close”
Figure 4-7 Session Control Command