CIE-H14A User Manual Ver. 1.4
- 40 -
6
Communication Modes
CIE-H14A provides RS232 to TCP/IP conversion function along with input/output port
monitoring and controlling function.
6.1
TCP Server
In this mode, CIE-H14A functions as a TCP server. CIE-H14A waits for a TCP connection
from remote hosts. Once one of hosts tries to connect to CIE-H14A, it responses to that
request. After the connection is established, CIE-H14A converts the raw data from the serial
port to TCP/IP packets and sends the packets to the network and vice versa.
6.1.1
Key parameters
⚫
Local Port
This is a server
’
s port number which is used in the TCP connection.
⚫
Event Byte
With setting event bytes, users can handle the serial data received before a TCP
connection is established.
Value
Description
0
CIE-H14A does not send the data received before a TCP
connection is established.
Otherwise
(512 or under)
CIE-H14A sends the data, which is received before a TCP
connection is established, right after a connection is established.
512 or under bytes are strongly recommended.
Table 6-1 Event Byte
⚫
Timeout
If there is no data transmission for the specific time, CIE-H14A terminates the
established TCP connection.
⚫
Notify IP Change
This function is for notifying information about changed IP address to a server. Not
only the TCP/UDP protocol but also Dynamic Domain Name Service (DDNS) can be
used.
⚫
Restriction of Access (ezTCP Firewall)
Users can block TCP connections from unauthorized hosts by using this option. Both
IP and MAC address are available.