Sollae Systems Co., Ltd.
https://www.ezTCP.com
4 ports Remote I/O Controller
CIE-H14A User Manual
Version 1.4
Страница 1: ...Sollae Systems Co Ltd https www ezTCP com 4 ports Remote I O Controller CIE H14A User Manual Version 1 4...
Страница 2: ...ensuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused by inappropriate disposal of th...
Страница 3: ...Interface 16 1 5 6 System LED 17 1 5 7 ISP Switch 18 2 Installation and Test 19 2 1 Installation 19 2 1 1 Setting Network Aera 19 2 2 Test operation 21 2 2 1 Modbus TCP Test 21 2 2 2 HTTP Test with a...
Страница 4: ...Connection Modes 33 5 1 5 Initial Output Value 33 5 1 6 Write Pulse 33 5 1 7 Communication with HMI 34 5 2 Serialized Modbus TCP 36 5 3 Macro Mode 36 5 3 1 Operator 36 5 3 2 Operand 37 5 3 3 An Examp...
Страница 5: ...e 65 8 2 2 Sending MAC Address 66 8 2 3 Debugging Message 66 8 3 Serial Port Tab Functions 68 8 3 1 TELNET COM port Control Option RFC 2217 68 8 3 2 Disable TCP Transmission Delay 68 8 3 3 Data Frame...
Страница 6: ...76 11 Technical Support and Warranty 77 11 1Technical Support 77 11 2Warranty 77 11 2 1 Free Repair Services 77 11 2 2 Charged Repair Services 77 12 Precaution and Exemption from Liability 78 12 1Prec...
Страница 7: ...functions CIE H14A is additionally equipped with a RS232 serial interface to allow users serial devices to establish an Ethernet networking connection so that it can be flexibly used in diverse applic...
Страница 8: ...ual Ver 1 4 7 https www ezTCP com 1 3 Application Examples Remote I O device server Figure 1 1 remote I O device server Serialized Modbus TCP Figure 1 2 serialized Modbus TCP Internet Switch Figure 1...
Страница 9: ...CIE H14A User Manual Ver 1 4 8 https www ezTCP com Serial Switch Figure 1 4 serial switch Macro mode Figure 1 5 macro mode Serial Device Server Figure 1 6 serial device server...
Страница 10: ...85 Certification KC CE Environment Follows Europe RoHS Directive Table 1 1 H W specification 1 4 2 S W specification Protocol TCP UDP IP ICMP ARP DHCP DNS lookup DDNS SMTP Telnet COM Port Control Opt...
Страница 11: ...s www ezTCP com 1 5 Interface 1 5 1 Power The Power is interfaced with a 5mm terminal block Input voltage range is DC 8 5 38V Please check the polarity Figure 1 7 Power Figure 1 8 Power polarity AC is...
Страница 12: ...of the input port is shown in the figure below Figure 1 9 a circuit of the input port The voltage specification of the input port is as follows Over 4 5V H 1 Under 1 2V L 0 Max Input Voltage DC 24V P...
Страница 13: ...r you can use a DCA Dry Contact Adapter so that you can give dry contact input signal Without DCA With DCA Input Condition 1 over DC4 5V between the input ports 0 under DC1 2V between the input ports...
Страница 14: ...ay contact 0 OFF open 1 ON short Table 1 5 values of the output port The allowed current of output port according to voltage condition is as follows Voltage Condition Allowed current DC 28V 5A Table 1...
Страница 15: ...output port is as follows Figure 1 11 CIE H14A output port The order of CIE H14A output ports is reversed compared to CIE H14 For those who use CIE H14A as a replacement of CIE H14 we recommend to che...
Страница 16: ...2 RXD Receive Data RS232 In Required 3 TXD Transmit Data RS232 Out Required 4 DTR Data Terminal Ready RS232 Out Optional 5 GND Ground Ground Required 6 DSR Data Set Ready RS232 In Optional 7 RTS Reque...
Страница 17: ...tomatically sense a 1 1 cable or cross over cable Each Ethernet device has its own hardware address MAC address CIE H14A is shipped to the market with the hardware address set in the factory Figure 1...
Страница 18: ...king Transferring data to the Ethernet Common Serial RXD Blinking Receiving data from the Serial TXD Blinking Transferring data to the Serial Normal mode STS Blinking every second Assigned an IP addre...
Страница 19: ...CIE H14A will go into the serial configuration mode that you can configure the environment parameters through the RS232 port If you press it over 1 second or supply power while pressing it CIE H14A wi...
Страница 20: ...port to a PC It will be no problem if the Ethernet connection is established through network hubs Figure 2 1 the connection between CIE H14A and a PC 2 1 1 Setting Network Aera This step is for settin...
Страница 21: ...of some major parameters are listed on the table below To make the test simple keep these values during the test parameter value Network Local IP Address 10 1 0 1 Subnet Mask 255 0 0 0 Option Telnet C...
Страница 22: ...CP In this instruction Modbus TCP test program was used Run ezManager Then you can see the window as shown below Figure 2 3 Modbus TCP test program of the ezManager Search the connected CIE H14A with...
Страница 23: ...nput the local port for Modbus TCP of CIE H14A In a local area network and steps can be omitted Connect by pressing Connect button Under the connection check if the Di LEDs are turned on or off with s...
Страница 24: ...t Input the IP address of your CIE H14A on the address field Ex 10 1 0 1 Check if DI LEDs are turned on or off with HIGH signal Check if DO LEDs are turned on or off with clicking the each of LEDs Pre...
Страница 25: ...ial appearance of ezManager 3 1 1 Configuration via LAN Checklists Make sure of the connection between your PC and CIE H14A via Ethernet If they are in the same network MAC Address search button can b...
Страница 26: ...e serial configuration mode by pressing the ISP button less than 1 second After then read the setting on the Serial tab Procedures Figure 3 3 procedures for configuration via serial port Step 2 Readin...
Страница 27: ...you can change some parameters through the serial port Figure 3 5 setting the communication mode to the AT command Procedures Figure 3 6 procedures for configuration with AT command Division Availabl...
Страница 28: ...able in this mode Serial configuration mode This mode is for configuring environmental parameters through the RS 232 port ISP mode This mode is for upgrading firmware and HTML files In addition you ca...
Страница 29: ...control I O and an additional operation which operates as a Serial to Ethernet converter I O controller Type Description Modbus TCP Control and monitor the I O of CIE H14A via Modbus TCP It supports...
Страница 30: ...ommunication modes 4 5 Serial Configuration mode 4 5 1 Configuring Parameters This is a mode for setting environmental parameters through the serial port If you cannot use the Network this mode is onl...
Страница 31: ...nager For more details about this please refer to the section 7 1 4 6 2 Upgrading HTML ISP mode can also upgrade HTML files For more details about this please refer to the section 4 6 3 Revoking Serur...
Страница 32: ...n Active Connection requesting a Modbus TCP connection Multiple Connection The numbers for multiple Modbus TCP connections Control Method of FC XX Control method for the output ports of the slave Sing...
Страница 33: ...rt Base Address 5 1 3 Modbus TCP Master Mode In this mode CIE H14A operates as a Modbus TCP master As a master CIE H14A transmits its input information to the salve and outputs the slave s input value...
Страница 34: ...Depending on the setting of multiple connections up to 8 hosts can be connected simultaneously The active connection CIE H14A tries to establish a connection to the remote host The IP address or host...
Страница 35: ...e Default Modbus Address Default HMI Address Di Word Read 03 0 40001 04 30001 Di0 Bit Read 02 0 10001 03 0 40001 0 04 30001 0 Di1 Read 02 1 10002 03 0 40001 1 04 30001 1 Di2 Read 02 2 10003 03 0 40001...
Страница 36: ...rite 05 15 105 Read 03 8 40009 1 Write 06 16 Do2 Read 01 10 00011 Write 05 15 105 Read 03 8 40009 2 Write 06 16 Do3 Read 01 11 00012 Write 05 15 105 Read 03 8 40009 3 Write 06 16 Table 5 5 Digital out...
Страница 37: ...ezManager to activate this mode If a port is set to Macro mode it cannot be controlled through HTTP or Modbus TCP 5 3 1 Operator The equation used in the Macro mode is Boolean algebra In this case the...
Страница 38: ...the two operands will be ignored Input Port Equations Description Do0 i0 i1 Perform OR for i0 and i1 Do2 i0 i1 i2 The part of the expression within the parentheses i1 i2 is evaluated first and then th...
Страница 39: ...s not required Leave blank or put a random name Password should be the same with a password which is set through the ezManager 5 4 1 Changing port number for HTTP In case you cannot use the port numbe...
Страница 40: ...e who can make HTML files If you get some simple syntax it is possible to monitor and control the I O ports with your homepage interface For more details about this please refer to 7 2 Changing Webpag...
Страница 41: ...setting event bytes users can handle the serial data received before a TCP connection is established Value Description 0 CIE H14A does not send the data received before a TCP connection is establishe...
Страница 42: ...to connection requests Remote host sends a connection request SYN segment Processes of the connection The connection is established Data communication is implemented on both sides Table 6 2 states of...
Страница 43: ...ens connection requests Remote host sends connection request SYN segment Processes of the connection The connection is established Data communication is implemented on both sides Table 6 3 states of e...
Страница 44: ...t Time States Data communication on both sides The last segment arrives at the CIE H14A No data communication for 5 seconds CIE H14A sends disconnection request FIN to a remote host Processes of the d...
Страница 45: ...st segments for the TCP connection with this parameter Value Description 0 CIE H14A sends a request segment of the TCP connection right after it boots up Otherwise 512 or under CIE H14A sends the segm...
Страница 46: ...n the Peer Port parameter 6 2 2 Examples A situation that Event Byte is set to 0 Figure 6 4 time chart Time States Power is not supplied yet CIE H14A sends a connection request segment right after it...
Страница 47: ...ent right after receiving 3 bytes processes of the TCP connection The connection is established The data 123 is transmitted to the remote host Table 6 8 states of each point As you can see CIE H14A ha...
Страница 48: ...State CIE H14A is waiting for request segments of a TCP connection The connection has been established CIE H14A is on line and processes of the disconnection The connection has been terminated Both si...
Страница 49: ...ocal Port at plp 1470 CR prip Peer IP Address at prip 10 1 0 2 CR prp Peer Port at prp 1470 CR pdc DHCP at pdc 1 CR On pto Timeout at pto 10 CR pwp Store setting at pwp CR Table 6 10 some of extended...
Страница 50: ...meters with AT commands ATA command has arrived CIE H14A listens to TCP connection requests A remote host has sent SYN segment to CIE H14A Processes of the TCP connection TCP connection has been estab...
Страница 51: ...CP connection Point State Configuring parameters with AT commands CIE H14A sends TCP connection request with the ATD command Processes of TCP connection TCP connection is established CIE H14A sends CO...
Страница 52: ...nection is off line CIE H4A sends FIN segment right after the ATH arrives processes of TCP disconnection TCP connection is terminated CIE H14A sends NO CARRIER with disconnection Table 6 13 states of...
Страница 53: ...ne block to the network The value is up to 1460 bytes Data Frame Interval Data Frame Interval means the time for gathering data to make them into a block Its unit is 10ms If there is no transmission f...
Страница 54: ...e Interval is 100 1s Point State CIE H14A is receiving data from the serial port CIE H14A Sends 5 bytes as one block based on the Block Size Serial device sends data 678 to CIE H14A Data 678 has arriv...
Страница 55: ...6 15 setting for dynamic update of peer host function Figure 6 11 Time chart for dynamic update of peer host Point State Sending any UDP data to the network is impossible UDP data arrives from Remote...
Страница 56: ...omepage when a new firmware is released You can find it on our website Entering ISP mode Enter ISP mode to download firmware file to CIE H14A Run a TFTP client and ready to send the F W file Run a TFT...
Страница 57: ...HTTP 7 2 2 Processes Making Users webpage or Downloading sample files Make your own webpage file or use sample webpage files freely available to download at our web site Entering ISP mode Enter ISP mo...
Страница 58: ...e client program Click the Advanced Menu Change F W HTML button Figure 7 3 running TFTP client Click Advanced Menu Change F W HTML menu to run TFTP client Select the Change HTML radio button Input the...
Страница 59: ...Using TELNET Once the TELNET option is activated users can remotely log in to CIE H14A If a password is set users should input the password After that messages from CIE H14A appear as shown in the fig...
Страница 60: ...nds command option description usage st net Network Status lsh st net sio Serial Port Status lsh st sio uptime System Uptime lsh st uptime sc OP1 OP2 Session Control lsh sc com1 close sd OP1 OP2 Captu...
Страница 61: ...mand displays the number of bytes for the serial port Figure 7 7 st sio command st uptime st uptime command shows amount of time since CIE H14A has booted up Figure 7 8 st uptime command sc sc command...
Страница 62: ...a OP1 means name of the session OP2 means period which has a 10ms unit for the capture Figure 7 10 sd command Below is the example of how to stop capturing a serial data Figure 7 11 serial data captur...
Страница 63: ...is automatically updated in every second Figure 7 13 status window of ezManager FIRMWARE VERSION The name of model and the version of firmware are displayed here SYSTEM UPTIME Operating time of CIE H...
Страница 64: ...s HIGH ON and 0 means LOW OFF ARP TABLE This part shows ARP table on CIE H14A When a TCP connection is established or UDP data communication is performed the information of IP and MAC address is autom...
Страница 65: ...ples IP Address Network Mask Allowed IP Address Range 10 1 0 1 255 0 0 0 10 1 0 1 10 255 255 254 10 1 0 1 255 255 255 0 10 1 0 1 10 1 0 254 192 168 1 4 255 255 255 255 192 168 1 4 Table 8 1 examples o...
Страница 66: ...t and create host names on the website of DynDNS before use this All about service usage of an account could be changed according to the policy of DynDNS Homepage of DynDNS http dyn com dns Figure 8 1...
Страница 67: ...ugging messages from CIE H14A on the network When you are facing a problem about the TCP connection or data communication use this function and send us the stored file We can use it for finding out th...
Страница 68: ...H14A over the network Auto update to display the latest captured file on the screen of MAC Address Information of a selected message Unavailable To start capturing debugging messages from CIE H14A To...
Страница 69: ...are changed 8 3 2 Disable TCP Transmission Delay If you use this option CIE H14A sends the data from the serial port to Ethernet as quickly as possible 8 3 3 Data Frame Interval Before sending data fr...
Страница 70: ...ient mode only In this mode you do not need to change the mode for switching active or passive TCP connection Note that the Event Byte option should be set to 1 or lager value 8 3 6 Separator Using th...
Страница 71: ...sing SMTP protocol When ports you selected are changed status of CIE H14A is sent to the Email address you entered Setting E mail notification option Figure 8 6 Notify Input or Output Port Change Chec...
Страница 72: ...CIE H14A User Manual Ver 1 4 71 https www ezTCP com Figure 8 7 I O port status notification email...
Страница 73: ...output ports later than the time set to Delay For example if Delay is set to 0 the output values are reflected to the output ports immediately Although it is allowed to set the values in 1ms it is acc...
Страница 74: ...programs have firewall functions so it can cause some trouble to search CIE H14A Close or pause these programs before searching the product Stable supply of the power Check if the power is supplied co...
Страница 75: ...need strong security the access may be denied by their firewall Under this circumstance users should ask the person in charge of their network to release ports which will be used Ex TCP 502 UDP 50005...
Страница 76: ...ted parameters that Unit ID Input Port Base Address Output Port Base Address Poll Interval and Notify Input change Checking which mode is using In the case of MACRO or serialized Modbus TCP you can co...
Страница 77: ...l Internet switch Serial switch Combinations of I O Controllers Digital Pulse Output Dry Contact Adapter DCA How to use a user s homepage IP Change Notification DDNS Sending MAC Address function TCP S...
Страница 78: ...ps www eztcp com en support qna php 11 2 Warranty 11 2 1 Free Repair Services For product failures occurring within 2 years after purchase Sollae Systems provides free repair services or exchange the...
Страница 79: ...d applications provided by Sollae Systems for purposes other than those for which they were designed is prohibited Do not use the product in an extremely cold or hot place or in a place where vibratio...
Страница 80: ...n financial losses damage to property personal injury or the death of people or animals If you use the CIE H14A voluntarily or involuntarily for such unauthorized applications you agree to subtract So...
Страница 81: ...it voiture camion train avion etc ni en milieu explosif ni dans des enceintes nucl aires ni dans des ascenseurs ni dans des a roports ni dans des enceintes hospitaliers ni pour des applications caract...
Страница 82: ...ments lectroniques usag s Le symbole de la poubelle barr pr sent sur le bo tier CIE H14A indique que vous ne pouvez pas vous d barrasser de ce dernier de la m me fa on que vos d chets courants Au cont...
Страница 83: ...nt Author 2019 07 02 1 0 Initial Release Amy Kim 2019 08 02 1 1 Update LED status table Amy Kim 2020 03 11 1 2 Add Input port Diagram Remove Component Sara Lee 2020 05 18 1 3 Add Output port image Sar...