4.7.5.2 Third party monitoring/control device connection
If a third party monitoring/control device need to be connected directly to the inverter, the
COM port can be used with a special connector to extend the RS485A and RS485B pins,
please contact Solis local service team or Solis sales for this special connector.
Modbus RTU protocol is supported by Solis inverters. To acquire latest protocol document,
please contact Solis local service team or Solis sales.
Figure 4.36
Figure 4.37
4.8 Meter Installation
The Solis S5-EH1P-L Series inverter is able to connected Acrel meters or Eastron meters
to fuilfill the control logic of the self-consumption mode, export power control, monitoring,
etc.
Acrel 1ph meter (With CT): ACR10R-D16TE (Optional)
Acrel 3ph meter (With CT): ACR10R-D16TE4 (Optional)
Eastron 1ph meter (Direct Insert): SDM120M (Optional)
Eastron 1ph meter (With CT): SDM120CT
Eastron 3ph meter (Direct Insert): SDM630 (Optional)
Eastron 3ph meter (With CT): SDM630MCT (Optional)
Below 4.8.1 section describes the connection diagram of 1ph meter Eastron SDM120CT
and Acrel ACR10R-D16TE.
Below 4.8.2 section describes the connection diagram of 3ph meter Eastron SDM630MCT
and Acrel ACR10R-D16TE4.
4. Installation
4. Installation
.28.
.27.
CAUTION:
Make sure the AC cable is totally isolated from AC power before
connecting the Smart Meter and CT.
A Smart Meter with the CT in product box is compulsory for hybrid system installation.
It can be
used to detect the grid voltages and current directions, provide the operating
condition of the hybrid
inverter via RS485 communications.
NOTE:
1. The Smart Meter with CT is already configured ; please do not change any
settings on the Smart Meter.
2. One Smart Meter can be used with only one hybrid inverter.
NOTE:
Please note that the CT orientation must be correct,
otherwise the system will not work properly
.
Grid
side
K
L
Compatible Smart Meter Model
SDM120CT (Default)
Pin 9 – RS485B, Pin 10 – RS485A
Pin 9 – RS485B, Pin 10 – RS485A
Pin 13 – RS485B, Pin 14 – RS485A
B – RS485B, A – RS485A
RJ45 Port on the meter
Pin 7 – RS485B, Pin 8 – RS485A
Pin 21 – RS485A, Pin 22 – RS485B
SDM120M
SDM630MCT
SDM630
ACR10R16DTE
ACR10R16DTE4
Meter RS485 Pin Definition
Table 4.7