ORIGIN User Guide
Origin Master Section
31
NOTE : If the
IN FRONT BALANCE
control is left fully clockwise (i.e. an all mix bus balance) then it may appear that
the AFL/Solo function isn't working as there is no AFL signal feeding the monitoring, (i.e. you're only listening to the
mix bus signal, i.e. no AFL/Solo signal)!
RED LIGHT
The
RED LIGHT
function closes a relay on the DB-9 UTILITY connector on the rear panel of the console. Typically this is used for
a Record Light for the studio, to indicate not to disturb the recording area. If nothing is connected to the UTILITY connector, then
this switch has no function (other than illuminating the associated red front panel LED!). The
RED LIGHT
relay switch closure will
change state when the console goes to SLEEP. This could be used to switch off other studio equipment, or to signal externally that
the console is in sleep mode, if the RED LIGHT function is not required.
METERS Section
MIX METER FOLLOW MON SOURCE
The
MIX
meter typically shows the level of the main stereo Mix bus. Pressing the
MIX METER FOLLOW MON
SOURCE
switch switches the
MIX
meter to follow the selection on the
MON SOURCE
section. This is useful
to meter, or calibrate an external source connected to one of the four External Source selectors.
PEAK MODE SELECT
The meters in ORIGIN are fast detecting 'peak' meters. These meters have some options for displaying peaks
and the
PEAK MODE SELECT
switch cycles around these modes with repeated pressing. The options are:
-
No Peak Hold. The meter displays instantaneous peak values only
-
First Press - 1 second Peak Hold. Peak level LED stays illuminated for approximately 1 second and
then automatically resets. This mode can be identified when selected by the red +24dBu LEDs
illuminating for approx. 1 second and then falling to the current metered level.
-
Second Press - 3 second Peak Hold. Peak level LED stays illuminated for approximately 3 seconds
and then automatically resets. This mode can be identified when selected by the red +24dBu LEDs
illuminating for approx. 3 seconds and then falling to the current metered level.
-
Third Press - Permanent Peak Hold. The LED indicating Peak level achieved stays illuminated
indefinitely and can be reset using the
PEAK CLEAR
function (see below). This mode can be identified
when selected by the red +24dBu LEDs rippling across 8 channel sections.
-
Fourth Press - returns to the no Peak Hold state.
The console will remember the setting when powered off, so the start state for the first press may be offset
(e.g. if in 1 second Peak hold when powered off, the next press after power on will be 3 second.)
PEAK CLEAR
Resets the captured Peak level (and indication) for all meters when permanent Peak Hold mode is selected (see
PEAK MODE
SELECT
above).
BUSES/STEREO SUBGROUPS
O R I G I N
24
23
22
21
20
19
18
15
12
9
6
4
0
4
6
8
10
12
15
18
21
25
28
32
L
R
dBu
24
23
22
21
20
19
18
15
12
9
6
4
0
4
6
8
10
12
15
18
21
25
28
32
A
1
2
24
23
22
21
20
19
18
15
12
9
6
4
0
4
6
8
10
12
15
18
21
25
28
32
L
R
dBu
B
3
4
24
23
22
21
20
19
18
15
12
9
6
4
0
4
6
8
10
12
15
18
21
25
28
32
L
R
dBu
C
5
6
24
23
22
21
20
19
18
15
12
9
6
4
0
4
6
8
10
12
15
18
21
25
28
32
L
R
dBu
D
7
8
24
23
22
21
20
19
18
15
12
9
6
4
0
4
6
8
10
12
15
18
21
25
28
32
L
R
dBu
E
9
10
24
23
22
21
20
19
18
15
12
9
6
4
0
4
6
8
10
12
15
18
21
25
28
32
L
R
dBu
F
11
12
24
23
22
21
20
19
18
15
12
9
6
4
0
4
6
8
10
12
15
18
21
25
28
32
L
R
dBu
G
13
14
L
R
dBu
H
15
16
24
23
22
21
20
19
18
17
16
15
14
12
10
8
6
4
0
4
6
8
10
12
14
16
18
20
22
24
26
30
35
40
MIX
L
R
dBu
Содержание ORIGIN
Страница 1: ...www solidstatelogic com ORIGIN User Guide ...
Страница 23: ...ORIGIN User Guide Detailed Channel Description 17 Channel Section Notes ...
Страница 55: ...49 ORIGIN User Guide Notes Notes ...
Страница 56: ...www solidstatelogic com ...