T
TR
R
S
So
of
ft
t
K
Ke
ey
ys
s
The
T
TR
R
soft keys allow Matrix’s Total Recall functions to be controlled from the console:
Total Recall is described on Page 53.
E
En
na
ab
bl
le
e
enables TR for restoring snapshots.
T
Ta
ak
ke
eT
TR
R
takes a TR snapshot.
S
Se
et
tS
Se
el
l
sets a TR snapshot to any channels selected using the upper
SEL
key.
S
Se
et
tA
Al
ll
l
sets a TR to the whole console.
C
Cu
ur
r:
:
displays the TR number which is currently selected in the
Total Recall
tab of the Matrix Remote.
I
IP
P
S
So
of
ft
t
K
Ke
ey
ys
s
The
I
IP
P
soft keys allow you to switch the console’s IP address between
F
Fi
ix
xe
ed
d
and
D
DH
HC
CP
P
.
The IP address information is shown after the
D
DH
HC
CP
P
button. By default, Matrix uses a fixed IP address of 192.168.1.2. with the
subnet mask set to 255.255.255.0.
See Page 5 for a description of how to change the fixed IP address.
See Page 4 for details of configuring the console’s Ethernet connectivity.
M
Miis
sc
c
S
So
of
ft
t
K
Ke
ey
ys
s
The
M
Mi
is
sc
c
soft keys cover miscellaneous Matrix settings:
I
In
np
pC
Cu
u
configures the channel
CUT
buttons. By default, pressing the channel
CUT
button mutes the channel output, leaving
any pre-fader feeds from the channel unaffected. Pressing
I
In
np
pC
Cu
u
causes the
CUT
buttons to mute the channel after the input,
muting any feeds from the channel that are not sourced from the
INPUT
.
O
Op
pt
tD
DA
AC
C
switches between the two digital inputs. By default, the AES (XLR) input is selected. Pressing the
O
Op
pt
tD
DA
AC
C
button
selects the S/PDIF input, and the button lights to indicate that this input has been selected.
Fader Options:
M
Ms
st
t+
+1
10
0
rescales the master fader. By default, the master fader reaches 0dB at the top, following the scaling labelled on the
left of the fader. Pressing
M
Ms
st
t+
+1
10
0
switches the meter’s scaling to reach +10dB at the top, following the labelling on the right
of the fader.
0
0d
dB
B
and
O
Of
ff
f
move the analogue faders on any channels selected using the upper
SEL
key to 0dB and -
∞∞
respectively.
Meter Signal Scale Option:
The default scale for all of the LED meters is meters is 0dBfs corresponds to an analogue level of +24dBu. The
+
+1
18
8d
dB
B
button
provides an alternative scaling of +18dBu.
USB Keyboard Identifier:
ey
yb
bI
ID
D
key is used to identify the nationality of keyboard being emulated by the Matrix USB soft keys. See Page 86 for
Chapter 3 - Analogue Signal Flow
44
Matrix Owner’s Manual
Содержание Matrix
Страница 36: ...This page is intentionally almost blank Chapter 2 Getting Started 28 Matrix Owner s Manual ...
Страница 102: ...This page is intentionally almost blank Chapter 6 DAW and CC Configuration 94 Matrix Owner s Manual ...
Страница 110: ...Appendix B Technical Specifications 102 Matrix Owner s Manual ...
Страница 114: ...This page is intentionally almost blank Appendix D Environmental Specifications 106 Matrix Owner s Manual ...
Страница 116: ...This page is intentionally almost blank Appendix E Software Updates 108 Matrix Owner s Manual ...
Страница 150: ...Appendix G Service 142 Matrix Owner s Manual ...
Страница 151: ...82S6MTS61A ...
Страница 152: ...82S6MTS62A ...
Страница 154: ...Appendix G Service 144 Matrix Owner s Manual ...
Страница 155: ...82S6MTW61A ...