Physical Requirements
Console Control Surface
The console control surface can be specified to have from 16 to 96 physical channels so the size and weight will vary
considerably.A dimensioned footprint drawing for each specific console control surface can be provided by SSL’s Project
Engineering Department. See page 46 for an example of a 32-channel footprint.
Consoles can be built with split points at any profile.The console can then be split for shipment to simplify installation into
client’s premises. Reassembly will be by SSL engineers.
Cable sets are available in 10, 16, 25, 48 and 80m standard lengths.
Cables for the connection of ancillary functions: meters, talkback or any custom switching etc. are not supplied by SSL
and will need to be provided by the facility. See pages 47–49 for wiring information.
Refer to Appendix A for weight and power consumption information.
Rack Mounting Equipment – Centuri, NetBridge and Stageboxes
The Centuri Processor is a 15U height chassis into which a range of I/O cards can be fitted.The system’s processing and
DSP resource is also housed in the Centuri rack.The Centuri is therefore fitted with cooling fans and is expected to be
housed in a separate ‘machine’ room.
A 19” equipment rack will need to be provided into which the Centuri Processor can be mounted. Note when positioning
the rack that cards are inserted into the Centuri Processor from both the front and the rear depending on function.
Clearance for access to cards must therefore be provided both in front of and behind the rack (see page 10 for service
clearance diagram).
A MIDI interface is supplied as standard on the C300HD. Access to the MIDI connectors is via a separate 1U breakout
panel which connects to the rear of the Centuri rack.A standard 800mm deep equipment rack will have sufficient room
for the panel to be located directly behind the Centuri. If shorter racks are used then an additional 1U of rack space must
be allocated for the panel. See page 45 for additional information.
NetBridge – which is an option – is a 2U high rack mounting unit.
Remotely located stageboxes (C-SBs) – which are also optional – may be specified.These are 14U rack units.
Centuri, NetBridge and stagebox units MUST be supported on shelves and not only by the rack ears.
Acoustic Isolation
Because of the noise generated by cooling fans the Centuri core should be located in a separate machine room.Adequate
noise isolation should exist between the machine room and control room/recording areas.
Noise figures for individual units are given in Appendix A.
Pre Installation Information
Section 3
Page 7
Содержание C300 HD
Страница 1: ...Installation Guide ...
Страница 2: ...C300HD Installation Guide ...
Страница 70: ...C300HD Installation Guide Page 66 4dBu 1 229V rms 0dBu 0 775V rms 6dBu 0 388V rms ...
Страница 74: ...C300HD Installation Guide Page 70 volume of a sphere 4 π r 3 3 ...
Страница 76: ...C300HD Installation Guide Page 72 Notes ...