background image

 

CARE AND CLEANING 

Clean your air conditioner to keep it looking new 
and to minimize dust build up. 

 

Air Filter Cleaning 

The air filter should be checked at least once 
every month to see if it needs cleaning. Trapped 
particles and dust can build up in the filter and 
may decrease airflow as well as cause the    
cooling coils to accumulate frost. To clean the air 
filter: 
 
1.  Remove the filter by pulling down on the in-

dents of the filter door on the front of the unit. 
(See FIG. 13) 

2. 

Wash the filter using liquid dish soap and 
warm water. Rinse the filter thoroughly. Gen-
tly shake the filter to remove excess water. 

 

3. 

Let the filter dry completely before placing it 
into the air conditioner.

 

4. 

If you do not wish to wash the filter, you may 
vacuum the filter to remove the dust and 
other particles.

 

 
 
 
 
 
 
 
 
 
 
 

Wear and Tear 

To minimize wear and tear on the air  condi-
tioner, always wait at least 3 minutes before 
changing modes. This will help prevent the   
compressor from overheating and the circuit 
breaker from tripping. 

Cabinet Cleaning 

To clean the air conditioner cabinet:  

• 

Unplug the air conditioner to prevent shock or 
a fire hazard. The cabinet and front panel of 
the air conditioner may be dusted with an oil-
free cloth or washed with a cloth dampened in 
a solution of warm water and mild liquid soap. 
Rinse thoroughly with a damp cloth and wipe 
dry. 

• 

Never use harsh cleaners, wax or polish on 
the cabinet front. 

• 

Be sure to wring excess water from the cloth 
before wiping around the controls. Excess 
water in or around the controls may cause 
damage to the air conditioner. 

 

Winter Storage

 

To store the air conditioner when it is not in use 
for an extended period of time, remove it care-
fully from the window according to the installation 
instructions and cover it with plastic or place it in 
the original box 
.

 

FIG. 13 

18

 

Содержание SG-WAC-25ESE-C

Страница 1: ...Models SG WAC 25ESE C Electronic Window Air Conditioner Operating Instructions V 121012...

Страница 2: ......

Страница 3: ...ad this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outline...

Страница 4: ...e The power supply cord must be replaced if it fails to trip when the TEST button is pressed and the unit fails to reset Do not use the power supply cord as an ON OFF switch The power supply cord is d...

Страница 5: ...es 2 Top Mounting Rail Foam Top Mounting Rail Seal Strip Accordion Panels 2 Side Retainer 2 Window Sash Seal Foam Seal for Bottom Rail Owner s Manual 5 SEAL BOTTOM RAIL TO UNIT SIDE RETAINER FRAME ASS...

Страница 6: ...ATION OF THE MANUFACTURER SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN Model SG WAC 25ESE C Power Supply Ph V Hz 1 230 208 60H...

Страница 7: ...o tilt enough for proper drainage See FIG 2 Prior to Installing the Air Conditioner 1 Check for anything that could block airflow Check the area outside of the window for things such as shrubs trees o...

Страница 8: ...emove and place to the side 3 Locate the four faceplate screws and remove These screws will need to be re installed prior to mounting the air con ditioner FIG 2 above 4 After removing the screws gentl...

Страница 9: ...m the top of the unit and both sides of the cabinet if installed FIG 6 7 7 Hold the cabinet while pulling on the base handle to carefully remove the unit Do not pull or lift near the top of the unit F...

Страница 10: ...ver the screws Top Angle Rail and Side Bracket Installation 1 Place the air conditioner on a hard flat surface 2 Locate the foam gasket and top angle rail 3 Attach the foam gasket to the top angle rai...

Страница 11: ...cabinet as shown below 4 Tighten all 6 bolts securely Extend the Accordion Panels 1 Carefully raise the window to expose the accordion panel and panel frame Loosen the locking screws so the accordion...

Страница 12: ...specified below MAX WALL THICKNESS 8 1 4 IMPORTANT The side louvers must never be blocked NOTE All parts needed for Thru The Wall Installation are provided except a wood frame shims and 10 wood screw...

Страница 13: ...uld be flush with the dry wall NOTE If wall thickness is 8 12 or more add aluminum flashing over the bottom of the frame opening to assure water is unable to enter the area between the inner and outer...

Страница 14: ...UCTION 1 Cut or build a wall opening in the masonry wall similar to the frame construction refer to the THRU THE WALL installation for a wall thickness greater than 8 1 2 2 Secure the cabinet in place...

Страница 15: ...ight will turn on while setting Auto off Timer When the air conditioner is on it can be set to automatically turn off in 0 5 24 hours To set the Auto off Timer press the TIMER button on the unit or re...

Страница 16: ...ner will cool the area depending on the location and set temperature of the remote control Take the remote control with you so the air conditioner cools the room to your loca tion The Remote must be i...

Страница 17: ...MODE and buttons at the same time 11 DISPLAY LIGHTS Hold the and FAN buttons to turn the lights on the display ON or OFF This can be done when the unit is on or off 12 ENERGY SAVER MODE When the unit...

Страница 18: ...Fan to Low with the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take app...

Страница 19: ...ar To minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from tripping C...

Страница 20: ...e technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold...

Страница 21: ...is not correctly tilted outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture remo...

Страница 22: ...be performed by a qualified HVAC contractor Soleus maintains a centralized service network to provide parts and assist in resolving service problems if difficulties are encountered Soleus agrees to pr...

Страница 23: ......

Страница 24: ......

Отзывы: