background image

the lowest and the fan speed at the highest.    Reducing the length of the exhaust hoses, insulating the 
exhaust hoses, and keeping direct sunlight to a minimum will also improve the cooling efficiency.   

 

 
DEHUMIDIFYING   

1.

 

Properly install the exhaust hoses.   

2.

 

Plug the power cord into a grounded outlet. 

3.

 

Turn on the unit by pressing the On/Off button on the control panel. 

4.

 

Press the Mode button until the “

” icon appears on the multi-color display. 

NOTE

:    The unit operates at low fan speed during dehumidifying.    The unit cools the room slightly 

during dehumidification. 

Keep the windows and the doors closed to aid in the effectiveness of the unit in removing the moisture 
from the room. 

NOTE

:    The unit will not dehumidify when the room temperature is lower than 61

°

F.  

 

FANNING 

1.

 

Plug the power cord into a grounded outlet. 

2.

 

Turn on the unit by pressing the On/Off button on the control panel. 

3.

 

Press the Mode button until “

” icon appears on the multi-color display. 

4.

 

Select the fan speed by pressing the Fan button. 

NOTE

: When the unit is running on fan mode, the exhaust hoses are inoperative and are not required.   

HEATING  

1.

 

Plug the power cord into a grounded outlet. 

2.

 

Turn on the unit by pressing the On/Off button on the control panel. 

3.

 

Press the Mode button until “

” icon appears on the multi-color display. 

4.

 

Press the 

 or 

 button until the desired room temperature appears on the 

multi-color display.    The temperature ranges from 61

°

F - 88

°

F (16

°

C - 31

°

C). 

5.

 

Select the fan speed by pressing the Fan button.    It is recommended to use the 
low fan speed.   

NOTE:    When the unit is running on heating mode, the exhaust hoses are inoperative and are not 
required.  

 

AUTO MODE 

1.

 

Properly install the exhaust hoses.   

2.

 

Plug the power cord into a grounded outlet. 

3.

 

Turn on the unit by pressing the On/Off button on the control panel. 

4.

 

Press the Mode button until the “

” icon appears on the multi-color display. 

5.

 

Press the Fan button to select the fan speed.   

During the Auto mode, the unit operates in heating mode when the room temperature is below 68

°

F.  

The unit operates in dehumidifying mode when the room temperature is between 68

°

F - 73

°

F.  The 

unit operates in cooling mode when the room temperature is above 73

°

F.  You may use the timer with 

the Auto mode. 

 

 
 
 

 

11

Содержание KY-34

Страница 1: ...Portable Air Conditioner Dehumidifier Heater and Fan utilizing Heat Pump Technology OWNER S MANUAL Model KY 34 Please read owner s manual carefully before operating unit 3046364...

Страница 2: ...NELAND MULTI COLOR DISPLAY 9 CONTROL PANEL FUNCTIONS 10 OPERATION USING THE CONTROL PANEL 10 COOLING 10 DEHUMIDIFYING 11 FANNING 11 HEATING 11 AUTO MODE 11 SLEEP MODE 12 REMOTE CONTROL OPERATION 12 MA...

Страница 3: ...operating as an air conditioner this unit is designed for spot cooling or cooling a room no larger than 550 square feet with a standard eight foot ceiling height When using this appliance always exer...

Страница 4: ...upervision is necessary when the unit is used near children The unit in not intended for use by children 10 Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills 11 Do...

Страница 5: ...t grounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check...

Страница 6: ...Cable power cord and plug BACK A Hot air outlet grill B Lower air inlet grill ACCESSORIES Flexible exhaust hose with adapters 3 piece set stretches from 14 1 4 to 60 5 8 36cm to 150cm Window exhaust...

Страница 7: ...ST HOSE Slide the square end of the exhaust duct over the hot air outlet on the back of the unit The exhaust hose should be kept as short and straight as possible Prevent any sharp bends in the exhaus...

Страница 8: ...sliding door and adjust the length of the window kit to fit the opening Mark and cut down a single panel of the window kit if necessary 2 Place the window kit between the window and the window frame a...

Страница 9: ...ases the room temperature timer hours Button This button increases the room temperature timer hours Power Button Press this button to turn the unit on or off MODE Button Press this button to select am...

Страница 10: ...o set the auto stop time press the Timer Off button and the multi color display will show a flashing Press the and buttons to change the clock to the desired time for the unit to automatically stop Th...

Страница 11: ...en the unit is running on fan mode the exhaust hoses are inoperative and are not required HEATING 1 Plug the power cord into a grounded outlet 2 Turn on the unit by pressing the On Off button on the c...

Страница 12: ...n 6 When in dehumidify mode the temperature will not change NOTE If the unit is turned off during cooling dehumidifying or heating and then restarted there will be a 3 minute delay before the compress...

Страница 13: ...r container is full 2 Place the drain pan accessory under the drainage port at the back of the unit 3 Remove the rubber plug from the drain hole The condensate water will drain out automatically When...

Страница 14: ...ide the filters out from the side of the unit Immerse the filter gently in warm water with a mild detergent Rinse thoroughly and dry before replacing An unclean air filter reduces air volume The filte...

Страница 15: ...at low Increase the fan speed Unit is noisy or vibrates Is the machine positioned unevenly on a level surface Place the unit on a level surface Is the voltage from the power source correct Use a prope...

Страница 16: ...e 115 V 60 HZ 115 V 60 HZ 115 V 60 HZ Cooling 12 A 11 7 A 9 8 A Rated Current Heating 9 8 A 9 5 A 8 8 A Sound Pressure Level 49 db A 49 db A 49 db A Weight 80 lbs 80 lbs 78 lbs Dimensions 14 4 x 22 4...

Страница 17: ...d by wear 4 Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus International Inc 5 Freight and Insurance cost for the warranty service ALL WARRANTIES I...