CONTROL PANEL FUNCTIONS 

 

ON/OFF BUTTON

 

Starts or stops the unit.   

MODE BUTTON

 

Press to select the operating mode:   
Fan Mode 
Air Conditioning Mode 
Heating Mode 
Dehumidifying Mode 
Auto Mode 

FAN BUTTON

 

Press to select the fan speed: High, Medium, and Low. 
The fan speed can be visually distinguished by the number of the digital air segments (follow arrow 
above) flow out from the windmill fan image on the multi-color display.

 

TEMPERATURE

 

When in cooling or heating mode, the desired temperature can be selected by pressing the 

 and 

 

buttons. The multi-color display flashes the temperature while it is being set. The multi-color display 
shows the set temperature when it is not in temperature setting mode.   

The multi-color display can show either Celsius or Fahrenheit.  Press the 

 and 

 buttons 

simultaneously to change the display from Celsius to Fahrenheit or vice versa.   

TIMER

 

To set the auto start time, press the Timer on button until the multi-color display shows a flashing 

”.  Press the 

 and 

  buttons to change the clock to the desired time for the unit to 

automatically start.    To set the auto stop time, press the Timer Off button and the multi-color display 

will show a flashing “

”.  Press the 

 and 

 buttons to change the clock to the desired time 

for the unit to automatically stop.  The light will flash for 3 seconds to activate the timer you 
programmed.  

TIME DISPLAY

In the diagram above, the letter “J” points to the adjustable time display. To adjust the time, Press FAN, 
SPEED and SWING together (at the same time), then press UP to adjust the hours, and press DOWN 
to adjust the minutes.   
 

SWING

 

To start horizontal oscillation, press the Swing button once. ‘

’ icon will appear on the multi-color 

display. To stop oscillation, press the Swing button again. Vertical air flow direction can be adjusted 
manually.

       

 
 

OPERATION USING THE CONTROL PANEL 

 

COOLING  

1.

 

Properly install the exhaust hoses. 

2.

 

Plug the power cord into a grounded outlet. 

3.

 

Turn on the unit by pressing the On/Off button on the control panel. 

4.

 

Press the Mode button until “

” icon appears on the multi-color display. 

5.

 

Press the 

 or 

 buttons until the desired temperature appears on the multi-color 

display. The temperature ranges from 61

°

F - 88

°

F (16

°

C - 31

°

C). 

6.

 

Select the fan speed by pressing the Fan button. 

NOTE

: During hot days, the unit will cool off the room most efficiently by setting the temperature at 

Содержание KY-34

Страница 1: ...Portable Air Conditioner Dehumidifier Heater and Fan utilizing Heat Pump Technology OWNER S MANUAL Model KY 34 Please read owner s manual carefully before operating unit 3046364...

Страница 2: ...NELAND MULTI COLOR DISPLAY 9 CONTROL PANEL FUNCTIONS 10 OPERATION USING THE CONTROL PANEL 10 COOLING 10 DEHUMIDIFYING 11 FANNING 11 HEATING 11 AUTO MODE 11 SLEEP MODE 12 REMOTE CONTROL OPERATION 12 MA...

Страница 3: ...operating as an air conditioner this unit is designed for spot cooling or cooling a room no larger than 550 square feet with a standard eight foot ceiling height When using this appliance always exer...

Страница 4: ...upervision is necessary when the unit is used near children The unit in not intended for use by children 10 Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills 11 Do...

Страница 5: ...t grounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check...

Страница 6: ...Cable power cord and plug BACK A Hot air outlet grill B Lower air inlet grill ACCESSORIES Flexible exhaust hose with adapters 3 piece set stretches from 14 1 4 to 60 5 8 36cm to 150cm Window exhaust...

Страница 7: ...ST HOSE Slide the square end of the exhaust duct over the hot air outlet on the back of the unit The exhaust hose should be kept as short and straight as possible Prevent any sharp bends in the exhaus...

Страница 8: ...sliding door and adjust the length of the window kit to fit the opening Mark and cut down a single panel of the window kit if necessary 2 Place the window kit between the window and the window frame a...

Страница 9: ...ases the room temperature timer hours Button This button increases the room temperature timer hours Power Button Press this button to turn the unit on or off MODE Button Press this button to select am...

Страница 10: ...o set the auto stop time press the Timer Off button and the multi color display will show a flashing Press the and buttons to change the clock to the desired time for the unit to automatically stop Th...

Страница 11: ...en the unit is running on fan mode the exhaust hoses are inoperative and are not required HEATING 1 Plug the power cord into a grounded outlet 2 Turn on the unit by pressing the On Off button on the c...

Страница 12: ...n 6 When in dehumidify mode the temperature will not change NOTE If the unit is turned off during cooling dehumidifying or heating and then restarted there will be a 3 minute delay before the compress...

Страница 13: ...r container is full 2 Place the drain pan accessory under the drainage port at the back of the unit 3 Remove the rubber plug from the drain hole The condensate water will drain out automatically When...

Страница 14: ...ide the filters out from the side of the unit Immerse the filter gently in warm water with a mild detergent Rinse thoroughly and dry before replacing An unclean air filter reduces air volume The filte...

Страница 15: ...at low Increase the fan speed Unit is noisy or vibrates Is the machine positioned unevenly on a level surface Place the unit on a level surface Is the voltage from the power source correct Use a prope...

Страница 16: ...e 115 V 60 HZ 115 V 60 HZ 115 V 60 HZ Cooling 12 A 11 7 A 9 8 A Rated Current Heating 9 8 A 9 5 A 8 8 A Sound Pressure Level 49 db A 49 db A 49 db A Weight 80 lbs 80 lbs 78 lbs Dimensions 14 4 x 22 4...

Страница 17: ...d by wear 4 Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus International Inc 5 Freight and Insurance cost for the warranty service ALL WARRANTIES I...