background image

 

4

IMPORTANT SAFEGUARDS 

 

Before installing and using your portable air conditioner and heater, it is important that you read this owner’s 
manual carefully. Store this manual in a safe place for future reference.   

 

This instruction manual is used for guidance and does not form part of a contract. It reserves the right to 
make technical changes without prior notice. 
 

1.

 

Always place the unit on a level surface. 

2.

 

The appliance shall be installed in accordance with national wiring regulation. 

3.

 

The unit must be connected to a correctly grounded power supply. For your safety, this unit is 
grounded through the power cord plug when connected to a grounded wall outlet. Do not use an 
adapter plug or extension cord. 

4.

 

Do not install the unit in an area where gas leakage may occur and/or in an explosive atmosphere.   

5.

 

Do not apply an insecticide or any type of flammable spray on the unit. 

6.

 

Confirm drainage piping is connected properly. 

7.

 

Do not start or stop the unit by inserting or pulling out the power plug. 

8.

 

Do not operate with wet hands. 

9.

 

Close supervision is necessary when the unit is used near children. The unit in not intended for use 
by children.   

10.

 

Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills.   

11.

 

Do not expose skin or eyes directly to cool air for a long period of time. 

12.

 

If an abnormal odor or smoke comes out of the unit, disconnect the unit immediately and contact a 
qualified service technician. (see page 13) 

13.

 

When opening the filter cover, do not touch the metal parts in the unit’s interior.   

14.

 

Do not immerse the unit in water or any type of liquid. Do not use the unit in the immediate 
surroundings of a bath, shower, or swimming pool, or in any other steamy, wet areas.   

15.

 

When cleaning the unit, always turn the unit off and unplug the power cord. 

16.

 

Always inspect the power cord for signs of damage before use. If the power cord is damaged, it must 
be replaced by the manufacturer or a qualified service technician. 

17.

 

Do not place a plant or allow a pet in the direct path of the airflow to avoid injury. 

18.

 

Do not put a stove, etc, where it would be exposed to the direct airflow. It may affect combustion. 

19.

 

Do not sit on the unit or place anything on it. 

20.

 

Before storing, the water must be drained from the unit and the filters cleaned.   

 

Содержание KY-34

Страница 1: ...Portable Air Conditioner Dehumidifier Heater and Fan utilizing Heat Pump Technology OWNER S MANUAL Model KY 34 Please read owner s manual carefully before operating unit 3046364...

Страница 2: ...NELAND MULTI COLOR DISPLAY 9 CONTROL PANEL FUNCTIONS 10 OPERATION USING THE CONTROL PANEL 10 COOLING 10 DEHUMIDIFYING 11 FANNING 11 HEATING 11 AUTO MODE 11 SLEEP MODE 12 REMOTE CONTROL OPERATION 12 MA...

Страница 3: ...operating as an air conditioner this unit is designed for spot cooling or cooling a room no larger than 550 square feet with a standard eight foot ceiling height When using this appliance always exer...

Страница 4: ...upervision is necessary when the unit is used near children The unit in not intended for use by children 10 Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills 11 Do...

Страница 5: ...t grounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check...

Страница 6: ...Cable power cord and plug BACK A Hot air outlet grill B Lower air inlet grill ACCESSORIES Flexible exhaust hose with adapters 3 piece set stretches from 14 1 4 to 60 5 8 36cm to 150cm Window exhaust...

Страница 7: ...ST HOSE Slide the square end of the exhaust duct over the hot air outlet on the back of the unit The exhaust hose should be kept as short and straight as possible Prevent any sharp bends in the exhaus...

Страница 8: ...sliding door and adjust the length of the window kit to fit the opening Mark and cut down a single panel of the window kit if necessary 2 Place the window kit between the window and the window frame a...

Страница 9: ...ases the room temperature timer hours Button This button increases the room temperature timer hours Power Button Press this button to turn the unit on or off MODE Button Press this button to select am...

Страница 10: ...o set the auto stop time press the Timer Off button and the multi color display will show a flashing Press the and buttons to change the clock to the desired time for the unit to automatically stop Th...

Страница 11: ...en the unit is running on fan mode the exhaust hoses are inoperative and are not required HEATING 1 Plug the power cord into a grounded outlet 2 Turn on the unit by pressing the On Off button on the c...

Страница 12: ...n 6 When in dehumidify mode the temperature will not change NOTE If the unit is turned off during cooling dehumidifying or heating and then restarted there will be a 3 minute delay before the compress...

Страница 13: ...r container is full 2 Place the drain pan accessory under the drainage port at the back of the unit 3 Remove the rubber plug from the drain hole The condensate water will drain out automatically When...

Страница 14: ...ide the filters out from the side of the unit Immerse the filter gently in warm water with a mild detergent Rinse thoroughly and dry before replacing An unclean air filter reduces air volume The filte...

Страница 15: ...at low Increase the fan speed Unit is noisy or vibrates Is the machine positioned unevenly on a level surface Place the unit on a level surface Is the voltage from the power source correct Use a prope...

Страница 16: ...e 115 V 60 HZ 115 V 60 HZ 115 V 60 HZ Cooling 12 A 11 7 A 9 8 A Rated Current Heating 9 8 A 9 5 A 8 8 A Sound Pressure Level 49 db A 49 db A 49 db A Weight 80 lbs 80 lbs 78 lbs Dimensions 14 4 x 22 4...

Страница 17: ...d by wear 4 Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus International Inc 5 Freight and Insurance cost for the warranty service ALL WARRANTIES I...