background image

10

COMPRESSOR

The compressor is hermetically sealed, permanently lubri-

cated and requires no additional oiling.

FRONT PANEL AND GRILLE

The front panel and grille can be cleaned with a mild soap or

detergent.  Do not use hydrocarbon-based cleaners (e.g.

acetone, benzene, naphtha, gasoline, etc.) to clean the front

panel or grille.  Use care when cleaning the control area.  Do

not use an excessively wet cleaning cloth.

SCHEDULED MAINTENANCE

To achieve continuing top performance and high efficiency,

a regular cleaning/inspection schedule must be established.

Maintaining this schedule can be accomplished by either a

local maintenance staff or an authorized servicer and must

follow the instructions described in this manual.

• If the unit is operated in a dusty climate, dust may collect

in the basepan and clog the condenser coil.  It is

advisable to remove the unit from the sleeve and thor-

oughly clean the basepan and condenser coil on a

periodic basis.

• If the unit is installed ocean side or in a corrosive

atmosphere, its life may be greatly reduced by the

corrosive environment.  Under these conditions, the unit

should be removed from the sleeve and completely

cleaned once a year.  At that time any scratches or

blisters on the painted surfaces should be sanded and

repainted.

OUTDOOR COIL CLEANING

The coils on the outdoor side of the air conditioner should be

checked regularly. For cleaning outside coil, remove the 6

screws that mount the condenser coil top cover to condenser

shroud.

Normal Operating Sounds and Conditions

POPPING OR GURGLING SOUNDS

This sound is the refrigerant traveling through the lines.  This

is a normal sound which may be heard for a few seconds after

the unit shuts off.

WATER TRICKLING SOUNDS

This sound is produced by the water as it is picked up and

run over the coils.  This procedure improves the efficiency of

the unit and helps with water removal.

WATER DRIPPING

Water will collect in the basepan during high humidity days.

STARTING DELAY

You may notice a short delay in the startup if you try to restart

the unit too soon after turning it off or if you adjust the

thermostat right after the compressor has shut off.  This

delay protects the compressor.

Obtaining Service

In the unlikely event this unit requires repair or servicing

beyond what is covered in this manual, contact an autho-

rized service organization.
To obtain an authorized servicer, contact your sales repre-

sentative or agency.

Содержание KTW-08

Страница 1: ...stallation Instructions and Owner s Manual This manual must be left with the owner of the equipment Model KTW 08 10 12 12H 2008 Soleus Air International Thank you for selecting Soleus Air To ensure proper operation please read this manual keep it for future reference ...

Страница 2: ......

Страница 3: ...ealers have a list of specific good safety practices follow them The precautions listed in this Installation Manual areintendedassupplementaltoexistingpractices However ifthereisadirectconflictbetweenexisting practices and the content of this manual the precautions listed here take precedence RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION Contents IMPORTANT NOTE TO THE OWNER 1 IMPORTANT NOTE TO THE ...

Страница 4: ...event of damage 1 Note on the delivery receipt any visible damage to shipment or container 2 Notify carrier promptly and request an inspection 3 File the claim with the following supporting documents within the six month statute of limitations a Original Bill of Lading certified copy or indemnity bond b Original paid freight bill or indemnity c Original invoice or certified copy showing trade and ...

Страница 5: ...upplied with the wall sleeve for a complete description of the installation proce dure NOTE Wallsleeve PBWS01A isnotshippedwithchassis and must be purchased separately Wall Sleeve Outside Wall Outside Inside Level 1 4 Bubble Tilt To Outside Figure 2 CHASSISINSTALLATION 1 Remove front grille See Figure A Lift up on Filter Handle Figure A Thefrontgrillecanberemovedformorethoroughcleaning or to make ...

Страница 6: ...chassis into the sleeve Ensure thatthegroundwireisnotpinchedorinthepathofthe condenserfan 5 Loosen locking plate screw and rotate tab with tab behind wall case flange See Figure C then tighten locking plate screw Locking Plate Figure C 6 If outlet is on the left side of the unit route power cord as shown in Figure D Clamp Power Cord Figure D ...

Страница 7: ...at OPEN some inside air is exhausted outside Locating Hole Locating Hole Screw Hole Screw Hole OPEN position Mesh end toward back CLOSE position Mesh end toward front Figure E To open or close the vent 1 Removethefrontgrille 2 Remove the vent card screw 3 Remove the vent card turn it over and replace it by locating rear hole in card over locating pin inside air discharge and reattaching screw at f...

Страница 8: ...ng or life support for personsoranimalswhoareunabletoreact to the failure of this product Thefailureofanunattendedairconditioner mayresultinextremeheatintheconditioned space causing overheating or death of persons or animals Take proper precautionstoavoidunattendedoperation DISCHARGE AIR GRILLE Figure 5 IMPORTANTNOTES 1 The unit is equipped with a rubber grommet mounted compressor These grommets a...

Страница 9: ...Do Not Mix Alkaline Standare Carbon Zinc Or Rechargeable Nichel Cadmium Batteries NOTE The remote control will work normally after reset 5 senconds LOWERS TEMPERATURE OR TIME RAISES TEMPERATURE OR TIME SETS FAN SPEED SETS MODE DISPLAYS TEMPERATURE TIME TURNS UNIT ON OR OFF TIMER LOWERS TEMPERATURE OR TIME RAISES TEMPERATURE OR TIME SETS FAN SPEED SETS MODE DISPLAYS TEMPERATURE TIME TURNS UNIT ON O...

Страница 10: ... maintained anywhere between 55F 13 C and 80F 27 C for heating mode If you want the display to read the actual room temperature Select the fan only mode TO CHANGE FAN SPEEDS YOU WILL SEE THE SPEED CHOSEN LIGHT ON LIGHT ON YOU WILL SEE Note The fan speed will begin in HI then adjust to MED and LO as the room temperature conditions indictates For example in cooling if the room doesn t get too warm i...

Страница 11: ...l count down the timer remaining until start 8 7 5 7 etc The Delay Start mode automatically selects cooling with maximum Fan Speed The temperature maintained will be the same as previously set To change the set temperature press COOL then Up or Down arrows until the desired temperature is indicated on the display After 5 seconds the control will automatically change the display back to the hours r...

Страница 12: ...e Control will operate all the control panel features follow the same instructions The control will maintain any set temperature between 60F and 90F degrees cooling 55F and 80F heating The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Up and Down Temperature Selection Pads at the same time for 3 seconds The...

Страница 13: ...ditions theunit should be removed from the sleeve and completely cleaned once a year At that time any scratches or blisters on the painted surfaces should be sanded and repainted OUTDOORCOILCLEANING Thecoilsontheoutdoorsideoftheairconditionershouldbe checked regularly For cleaning outside coil remove the 6 screwsthatmountthecondensercoiltopcovertocondenser shroud NormalOperatingSoundsandConditions...

Страница 14: ...13 5 EER C O P 9 4 9 4 9 4 9 4 Noise Level dB A H M L 58 56 54 58 56 54 60 58 56 60 58 56 CFM 280 280 280 280 Design Pressure PSIG H L 400 psi 170psi 400 psi 170psi 400 psi 170psi 400 psi 170psi Dimension W H D 25 98x15 62x16 88 25 98x15 62x16 88 25 98x15 62x16 88 25 98x15 62x16 88 Packing Dimension W H D 29 64x18 22x24 4 29 64x18 22x24 4 29 64x18 22x24 4 29 64x18 22x24 4 Net Gross Weight Lb 72 26...

Страница 15: ... power line voltage fire flood or other Acts of God or normal wear and tear Warranty service must be performed by a qualified HVAC contractor Soleus maintains a centralized service network to provide parts and assist in resolving service problems if difficulties are encountered Soleus agrees to provide service information sell repair parts and reimburse the dealer serviceman for parts in accordanc...

Страница 16: ......

Отзывы: