
The vent control allows outside air to be drawn into the
conditioned area. This outside air can provide ventilation
when the blower is operating, but it will increase the
heating or cooling load and operating costs.
To obtain access to the vent control
1
.
Remove the cabinet front (see Front Removal).
2.
Remove the shipping screw (if installed) from the vent
door.
3.
Remove the label (if present) from over the vent control
lever on the left side of the chassis. Remove the vent door
shipping screw.
4. Rotate the vent control lever to either open or close
the damper.
Remove
shipping
screw
if
present
Fig 13
Shipping
Screw
Location
TIMER PROCEDURE
( Remote controller)
When cells are inserted, the present time is automatically
set to AM 0:00.EX.:set to AM10:30.
Open the back cover, push the CLK button .The time
indicator is flickering and can set the present time.
Press the HOUR button.(set to AM 10:00)
Press the MIN button.(set to 30)
Press the CLK button again, and then close the back
cover.
COOL/FAN/HEAT MODE OPERATION
PROCEDURE
Control panel:
Press the ON/OFF button.
Press the HEAT COOL FAN button, select the operation
mode:
heat cool fan.
Press + or - button, to set your desired temperature. The
setting temperature range is 60-90°F(16-32°C).
Press the FAN SPEED button, to set your desired air
flow rate:
high/ low auto.
°
°
auto
/
/
/
/
/
Remote controller:
Press the ON/OFF button with the remote controller
pointing toward the packaged terminal air conditioner.
Press the MODE button, select the operation mode:
cool/fan/heat.
Press + or - button, to set your desired temperature. The
setting temperature range is 61-88 F(16-31 C).
Press the FAN SPEED button, to set your desired air
flow rate:hig/ low/
.
VENTILATION CONTROL
The ventilation control lever is located at left side of unit,
behind front panel.
NOTE: The vent door shipping
tape must be removed before
using vent control lever. See Fig 12
and
Fig13.
When set at close
,
only the air inside the room is circulated
and filtered;
When set at open
,
some outdoor air will be drawn into room,
this will reduce heating or cooling efficiency.
-9-
:
unit
control
panel
has
control
of
unit
.
:
wall
thermostat
has
control
of
unit
.
67
R3
R1
R2
R4
R5
R6
R7
R8
Heating
Temperature
Limits
(
°
F
)
90
86
86
74
92
90
72
90
72
63
65
72
69
68
60
Cooling
Temperature
Limits
(
°F
)
11
12.
Fig 11
Fig 12 Shipping Screws Location