background image

powervent (pv)

CentrIFUGAL In LIne DUCt eXHAUSt FAnS
ventILADoreS CentrIFUGoS In-LIne
ventILAteUrS CentrIFUGeS en LIGne

Models pv-100, 100X, 125, 125X, 150, 150X, 
 

200, 200X, 250, 250X, 315, 315X

InStALLAtIon AnD wIrInG InStrUCtIonS

InStrUCCIoneS De MontAJe

InStrUCtIonS De MontAGe

(English / Español / Français)

READ AND SAVE THESE INSTRUCTIONS

LEER Y GUARDAR ESTAS INSTRUCCIONES

LIRE ET CONSERVER CES INSTRUCTIONS

C

U

R

UL

S

Содержание powervent PV-100

Страница 1: ...IFUGES EN LIGNE Models PV 100 100X 125 125X 150 150X 200 200X 250 250X 315 315X INSTALLATION AND WIRING INSTRUCTIONS INSTRUCCIONES DE MONTAJE INSTRUCTIONS DE MONTAGE English Español Français READ AND SAVE THESE INSTRUCTIONS LEER Y GUARDAR ESTAS INSTRUCCIONES LIRE ET CONSERVER CES INSTRUCTIONS C U R UL S ...

Страница 2: ...lador y hacer coincidir los agujeros ranurados en en el soporte con los del ventilador Atornillar y montar el ventilador Placer le ventilateur en faisant coïncider les orifices du support avec ceux du ventilateur puis placer les deux vis de fixation 3 Completely tighten both screws to secure the fan Colocar el otro tornillo y apretar ambos Bien serrer les deux vis de fixation 4 Wire the fan in acc...

Страница 3: ...TRICIDAD DE 120V 60Hz Figure 2 Electrical Wiring Conexión Eléctrica Raccordement Electrique Motor without Speed Controller Motor sin regulador de velocidad Moteur sans variateur de vitesse Motor with Speed Controller Motor con regulador de velocidad Moteur avec variateur de vitesse IMPORTANT TOUS LES POWERVENT SONT FOURNIS AVEC UN MOTEUR UNIQUEMENT ADAPTE À UNE ALIMENTATION ELECTRIQUE DE 120V 60Hz...

Страница 4: ...ntended by the manufacturer If you have any questions contact the manufacturer b Before servicing or cleaning the unit switch the power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel c Installati...

Страница 5: ...WERVENT Duct Fans Ductwork connection should be made with duct tape or duct fast clamps available through your local HVAC wholesale supplier to ensure a good seal and secure connection ELECTRICAL CONNECTION All POWERVENT series fans operate from a standard 120V 60Hz A C electrical supply All wiring must be ca rried out in accordance with National Electrical Code and all applicable state and local ...

Страница 6: ...ranty Claim with an accompanying description stating the nature of the fault THE FOLLOWING WARRANTIES DO NO APPLY Damages from shipping either concealed or visible Claim must be filed with the carrier Damages resulting from improper wiring or installation Damages caused by acts of nature or resulting from improper consumer procedures such as Improper Ma intenance Misuse Negligence Alteration Abuse...

Отзывы: