background image

(i) CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Mate-

rials And Vapors.

(j) CAUTION: This unit has an unguarded impeller. Do Not Use In Locations Readily Accessible To People 

Or Animals.

(k) All units are suitable for use with solid-state speed control.

The POWERVENT series can be mounted in any orientation, horizontal or vertical, and is suitable for numerous 
types of applications. 

If the installation is made to rigid or flexible ducting, then it is recommended that the correct diameter ducting 
be used to couple to the fan flanges. If it is necessary to bend the duct at the discharge of the fan then the bend 
radius should be as large as possible.

Before installing the product check the following points; (1) the fan impeller turns freely and (2) there are no 
obstructions to the airflow.

All models include a robust mounting bracket, which enables easy and quick installation of the fan. See Figure 
(1) 
Installation Diagrams For POWERVENT Duct Fans.

Ductwork connection should be made with duct tape or duct fast-clamps (available through your local HVAC 
wholesale supplier) to ensure a good seal and secure connection.

ELECTRICAL CONNECTION

All POWERVENT series fans operate from a standard 120V 60Hz A.C electrical supply. All wiring must be ca-
rried out in accordance with National Electrical Code,  and all applicable state and local buildings codes. 

Electrical connections should be made in accordance with the electrical wiring diagrams shown in Figure (2) 
Electrical Wiring.

MAINTENANCE

IMPORTANT:  BEFORE  CARRYING  OUT  ANY  MAINTENANCE  OR  SERVICING,  ENSURE  THE  UNIT  IS 
DISCONNECTED FROM THE MAINS ELECTRICAL SUPPLY.

All POWERVENT series exhaust fans incorporate sealed for life bearings and therefore do not require any lu-
brication. We would recommend inspection of the product at least once every twelve (12) months to avoid the 
excessive accumulation of dust and dirt on the impeller. To inspect the unit disconnect from electrical supply and 
remove from ducting. If any debris is evident on the impeller clean with a damp (not wet) cloth. DO NOT USE 
any detergents or abrasive materials for cleaning.

4

5

Содержание powervent PV-100

Страница 1: ...IFUGES EN LIGNE Models PV 100 100X 125 125X 150 150X 200 200X 250 250X 315 315X INSTALLATION AND WIRING INSTRUCTIONS INSTRUCCIONES DE MONTAJE INSTRUCTIONS DE MONTAGE English Español Français READ AND SAVE THESE INSTRUCTIONS LEER Y GUARDAR ESTAS INSTRUCCIONES LIRE ET CONSERVER CES INSTRUCTIONS C U R UL S ...

Страница 2: ...lador y hacer coincidir los agujeros ranurados en en el soporte con los del ventilador Atornillar y montar el ventilador Placer le ventilateur en faisant coïncider les orifices du support avec ceux du ventilateur puis placer les deux vis de fixation 3 Completely tighten both screws to secure the fan Colocar el otro tornillo y apretar ambos Bien serrer les deux vis de fixation 4 Wire the fan in acc...

Страница 3: ...TRICIDAD DE 120V 60Hz Figure 2 Electrical Wiring Conexión Eléctrica Raccordement Electrique Motor without Speed Controller Motor sin regulador de velocidad Moteur sans variateur de vitesse Motor with Speed Controller Motor con regulador de velocidad Moteur avec variateur de vitesse IMPORTANT TOUS LES POWERVENT SONT FOURNIS AVEC UN MOTEUR UNIQUEMENT ADAPTE À UNE ALIMENTATION ELECTRIQUE DE 120V 60Hz...

Страница 4: ...ntended by the manufacturer If you have any questions contact the manufacturer b Before servicing or cleaning the unit switch the power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel c Installati...

Страница 5: ...WERVENT Duct Fans Ductwork connection should be made with duct tape or duct fast clamps available through your local HVAC wholesale supplier to ensure a good seal and secure connection ELECTRICAL CONNECTION All POWERVENT series fans operate from a standard 120V 60Hz A C electrical supply All wiring must be ca rried out in accordance with National Electrical Code and all applicable state and local ...

Страница 6: ...ranty Claim with an accompanying description stating the nature of the fault THE FOLLOWING WARRANTIES DO NO APPLY Damages from shipping either concealed or visible Claim must be filed with the carrier Damages resulting from improper wiring or installation Damages caused by acts of nature or resulting from improper consumer procedures such as Improper Ma intenance Misuse Negligence Alteration Abuse...