Activation of absence mode (8):
During a period of prolonged absence, you can reduce the airflow of ventilation (Half
mini airflow).
To do this, navigate with the buttons 19 or 20 until 8 mode pictogram absence.
Select with key 18. The icon flashes. Confirm with 18.
•
Display of the saving (14):
The IDEO-HR enables you to view at any time gain Kilowatts per month that brings the
heat
recovery
system
compared
to
a
conventional
single
stream.
Hold the button 18 to display the gain.
•
Level of emission / reception of the remote control (9):
The remote communicates continuously with IDEO-HR (868 MHz). The level of
transmission / reception allows you to validate the quality of the signal.
If it is zero you can order a module more powerful.
Emission level standard antenna: 150 meters in open field
Optional antenna emission level: 200 meters in open field
•
Reading temperatures (15 and 16):
Temperatures “T in” and “T out” indicate the temperatures measured:
T in: Internal temperature from the remote control.
T out: outdoor temperature from the outdoor fresh air intake.
•
Terms of icon display filters (12):
This icon appears when one or more filters are dirty and should be cleaned or changed.
F1 = Filters on the supply air
F2 = Filters on the extract air
The duration of the fouling up can change depending on the conditions of use and the
area in which your home is located (what level of outdoor pollution is industrial, road or
vegetable).
Generally the duration change between 6 and 12 months.
Warning: If this icon appears at the start or after a few days, this indicates that the
ductwork is too complex (loss of excessive loads) and obliges the IDEO to work
Hereafter abilities).
•
Terms of the error icon (11):
This icon appears when a component is out of service (motor, sensor, sensor, .....). Or
the IDEO detects an error in the system (leak on the network, plug, ...). To know the
meaning of the error code displayed, refer to Chapter 8.
•
Terms of the automatic defrost icon (7):
The
IDEO
has
an
automatic
defrost
system
performance
and
cost.
The system automatically starts the operation before the temperature of the extraction
system and downstream of the exchanger is negative. Supply airflow is then reduced.
In case of extremely low temperatures can stop blowing. When the temperature returns
to positive supply airflow returns to 100%.
In regions where temperatures are regularly negative or can fall below -10 º C, it is advisable to