Sole Diesel 4 GSCH Скачать руководство пользователя страница 1

 

 

1

 

Rev. β 

 

 

 

U_ GBAV_EN, U_GBMV_EN, U_ GBBA_EN, U_GBNA_EN, U_ GCAS_EN, U_GCMS_EN,  
U_ GCAW_EN, U_GCMW_EN, U_ GDAT_EN, U_GDMT_EN, U_ GDAX_EN, U_GDMX_EN 

Rev. 3 

 

U_GQNG_EN 

Rev. 0 

 

Содержание 4 GSCH

Страница 1: ...1 Rev U_ GBAV_EN U_GBMV_EN U_ GBBA_EN U_GBNA_EN U_ GCAS_EN U_GCMS_EN U_ GCAW_EN U_GCMW_EN U_ GDAT_EN U_GDMT_EN U_ GDAX_EN U_GDMX_EN Rev 3 U_GQNG_EN Rev 0...

Страница 2: ...chosen place is away from the center line of the boat the reduced weight of the 4 GSCH will not influence the stability NOTICE The images text and information contained in this manual are based on th...

Страница 3: ...et 17 Section 3 Installation 18 3 1 Angular Operation 18 3 2 Genset Installation 18 3 2 1 For hand starting the engine by handle in emergency case 18 3 2 2 For a correct air replacement 19 3 2 3 For f...

Страница 4: ...1 5 2 Periodic Maintenance Schedule 33 5 3 Lubrication System 35 5 4 Exhaust System 35 5 4 Cooling System 37 5 5 Fuel System 39 5 6 Electrical System 40 Troubleshooting 43 WARNINGS 45 Sea Water Cock I...

Страница 5: ...23 Fig 18 Panel SPA 10 dimensions 23 Fig 19 Panel SPA 10 24 Fig 20 Panel SPA 10 yellow light Fig 21 Panel SPA 10 green light 24 Fig 22 Automatic Decompression Device 25 Fig 23 Automatic Decompression...

Страница 6: ...LIST OF TABLES Table 1 Technical Specifications 4 GSCH 13 Table 2 Limited warranty coverage periods 14 Table 3 Angular Operation 18 Table 5 Periodic maintenance schedule 34 Table 6 Troubleshooting 43...

Страница 7: ...el pump or other potential sources of spilled fuels or fuel vapors Never add fuel to the tank while the engine is running because spilled fuel may ignite on contact with hot parts or from sparks Catch...

Страница 8: ...special place Do not smoke or permit flames or sparks to occur near sources of spilled fuel or fuel vapors Dangers Hazardous voltage Operate the genset only when all guards and electrical enclosures...

Страница 9: ...l fatigue weakness in joints and muscles Sleepiness mental fatigue inability to concentrate or speak clearly blurred vision Stomachache vomiting nausea Fig 2 Warning Carbon monoxide Keep the area arou...

Страница 10: ...ng on the genset could impair its operation Fig 6 Caution label Not a step NOTICE 1 The installer operator of the genset has to wear suitable CLOTHING for the workplace and the situation in particular...

Страница 11: ...For an updated list of our international distribution network visit Dealers section in our web page www solediesel com Or request this information by contacting Sol Diesel at e mail info solediesel c...

Страница 12: ...set Identification MANUFACTURER SOL S A Road from Martorell to Gelida km 2 08760 MARTORELL BARCELONA SPAIN GENSET MODEL 4 GSCH 3000 rpm Genset has a little nameplate located on the canopy and another...

Страница 13: ...nson self priming directly driven Electrical System Auxiliary voltage for starting battery 12V 8A ALTERNATOR General Information Brushless AC generator maker V T E Italy Generator type Synchronous AC...

Страница 14: ...nt that the product is not immediately delivered to the end customer the warranty shall enter into force 6 months after the date of sale Any limited warranty period that has not elapsed can be transfe...

Страница 15: ...described in this manual d Deterioration resulting from not complying with the procedure for winter storage while the engine is not in service as described in this manual e Faults due to negligence l...

Страница 16: ...ter inspecting the goods if you notice damage write a reservation on the delivery note Have the carrier countersign the note and advise SOL S A preferably by mail sole solediesel com 2 2 Transporting...

Страница 17: ...client must check the possible conditions of conservation in relation to the place of storage If the genset is unused for prolonged periods and stored observe all the relative technical specifications...

Страница 18: ...the engine by handle in emergency case The operation has to be taken into consideration in case the boat remains for many months without up keeping and there is the risk to remain with the several bat...

Страница 19: ...nerator Select a location that will allow adequate space on all sides for ventilation and servicing Locate the generator away from living quarters and away from bilge splash and vapors The mounting pl...

Страница 20: ...he generator and the boat s mounting platform is a possible solution This will also improve the sound insulation For this plate use 3 cm thick wood that weighs 10 15 Kg and soft mounts that are rectan...

Страница 21: ...21 Rev Fig 14 Genset top view Fig 15 Genset base plate 3 2 4 External connections Fig 16 External connections...

Страница 22: ...is unobstructed FUEL LEVEL Check the fuel level and keep the tank s full to ensure adequate fuel supply OIL LEVEL Maintain the oil level below dipstick high mark and above dipstick low mark OPERATING...

Страница 23: ...ning for aborted starting attempt yellow LED blinking because the engine shut off valve remains energized and takes useless power from the starting battery If the yellow LED remains flashing when the...

Страница 24: ...ore starting This precaution will prevent damage caused by unanticipated operation of AC machinery and will prevent a cold engine from stalling 2 To start the generator push the START button on the Pa...

Страница 25: ...electric starting During engine operation the pointer on this device is in the operating 9 o clock position 2 Using a 10 mm wrench turn the hex head bolt on the device so the pointer is in the manual...

Страница 26: ...ession to start it The extra fuel device helps the operation providing more fuel from the injection pump There are two positions for the knob up off and down activated pull down to activate After star...

Страница 27: ...in the position shown in the illustration 9 Slowly crank the engine counter clockwise 4 times then crank the engine as fast as possible The pointer on the Automatic Decompression Device will automatic...

Страница 28: ...position and make a normal electrical starting attempt 6 If the result is poor repeat the operation Fig 26 Automatic Decompression Device INSPECTION AFTER STARTING UP LEAKEGE Check inside the capsule...

Страница 29: ...ore starting the genset again open the seawater cock Repeat this operation whenever the genset is used at temperatures below 0 C 2 Use oil with suitable quality and viscosity SAE 15W40 is recommended...

Страница 30: ...r every 500 liters of diesel 7 Clean and dry the area where the engine is installed 8 Loosen the belts 9 Apply dielectric spray on the electrical connection disassemble the battery and charge it sever...

Страница 31: ...emblies are functioning improperly When lifting or carrying heavy parts get someone to help you if the part is too awkward for one person to handle Use jacks and chain blocks when necessary Reassembly...

Страница 32: ...32 Fig 28 4 GSCH parts Fig 29 4 GSCH parts...

Страница 33: ...cedures should therefore be carried out solely by qualified electrical and mechanical specialists Before any maintenance and cleaning work make sure that there are no moving parts that the generator h...

Страница 34: ...CL I Fuel filter C Water separator filter if applicable E C Injection pump I Injector I Power system bleeding I Intake System Air filter I C C I Cooling System Salt water circuit I CL Water filter I...

Страница 35: ...e cause internal genset components to seize and or shorten genset life Never mix different types of genset oil This may adversely affect the lubricating properties of the genset oil Fig 30 Sol Diesel...

Страница 36: ...tead of the third muffler the water separator The cooling water is separately thrown from a separate hole flowing smoothly avoiding the noise produced by the water coming alternatively spread from the...

Страница 37: ...er circuit connected For a generator the water intake must be fitted into the direction causing vacuum because on the contrary a self water entrance can be caused when the boat is sailing and the set...

Страница 38: ...boat or producing warm water using the waste heat of the engine cooling system a pipe has to be connected according to the drawing Fig 35 Heat Recovery System The fiberglass capsule has not the two h...

Страница 39: ...use a failure in the non return valve of the feeding pump of the main engine can influence the set and voiceovers Fig 36 Fuel System NOTICE The injection pump of the 4 GSCH is self bleeding it means t...

Страница 40: ...harger Changeover switch shore generator As the most of the boats have installed 230 V feeding line from the shore it has to be absolutely avoided that the main and the generator remain contemporaneou...

Страница 41: ...41 Rev Fig 39 Shore board line Fig 40 Main Output...

Страница 42: ...42 Fig 41 Electrical Plant...

Страница 43: ...ltage over 240 V Engine speed too high Check and adjust rpm Capacitor with too high capacity Check and replace Low no load voltage under 230 V Engine speed too low Check and adjust rpm Faulty rotating...

Страница 44: ...44 MAIN VOLTAGE 230V AC MISSING Fig 42 Troubleshooting...

Страница 45: ...hysical rules Sea Water Cock Installation Sea water intake oriented towards sailing direction causing a dynamical pressure that when the generator is not running let flow sea water through the cooling...

Страница 46: ...below the sea level without a proper cooling pipe goose neck and vacuum siphon break valve If the set installation surface is just a little below the external sea water level but can be guessed that...

Страница 47: ...milk white yellow not transparent or worst an increased level into the sump mean water flooding Another water presence signal becomes from starting difficulties as due to some roost on the exhaust val...

Страница 48: ...Spraying into the combustion chamber some lubricating oil and disconnecting the exhaust pipe moving the piston position by the handle or a flash starting attempt avoids completely the roost risk for...

Страница 49: ...49 Rev U_GQNG_EN Rev 0...

Отзывы: