Solbrake

 (SMB)

 

 

 

Electronic Motor Brake (DC Injection) 

8 - 390A, 220 - 690V

 

 

 

 

I

I

n

n

s

s

t

t

r

r

u

u

c

c

t

t

i

i

o

o

n

n

 

 

M

M

a

a

n

n

u

u

a

a

l

 

Ver.11.0/11. 2002 

 

 

 

Содержание Solbrake

Страница 1: ...Solbrake SMB Electronic Motor Brake DC Injection 8 390A 220 690V I In ns st tr ru uc ct ti io on n M Ma an nu ua al l Ver 11 0 11 2002 1...

Страница 2: ...ction IP00 ATTENTION 1 This product was designed and tested for compliance with IEC947 4 2 for class A equipment 2 The Solbrake SMB brakes are designed to meet UL requirements 3 Use of the product in...

Страница 3: ...ect the brake according to the following criteria Motor Current starting conditions Motor s Full Load Ampere FLA as indicated on its nameplate even if the motor is not fully loaded The Solbrake SMB is...

Страница 4: ...tected against short circuit by fast acting fuses Recommended I2 t values in page 9 Transient Protection Line transient voltages can cause malfunctioning of the brake and damage to the SCRs When high...

Страница 5: ...commended to apply some minimal inertia on the motor shaft The Solbrake SMB incorporates the following built in time delays t1 DC Injection Brake Contactor Motor Contactor 1 2 Open t2 t3 t4 t5 1 2 Clo...

Страница 6: ...ls L1 and L2 internal contact Ca in Solbrake SMB controlling motor contactor closes after Mains voltage is connected and terminal 1 2 are open When operating in Manual mode DC injection will stop afte...

Страница 7: ...L C1 C2 SMB Control M L1 L2 U V W C2 O L 1 2 SMB Power 3 4 5 6 Ca Cb C2 1 Cr 2 Stop O L Cf C2 SMB Control Start Forward Cf 2 Cr 1 Cf 1 Cr 3 Cf 4 Cr Start Reverse Cf 3 Cr 4 Cf Cr Reversing C2 SMB Cont...

Страница 8: ...g has ceased and motor is still turning increase braking Torque setting and try again b If motor has stopped and the Yellow LED remains on decrease Braking Time setting until the Yellow LED turns off...

Страница 9: ...C 000 BS 88 180 C330144 H600399 Solbrake SMB 105 100000 GSGB350 500V 350A 6 6 URD 2x000 BS 88 355 V330160 H600399 Solbrake SMB 210 600000 GSGB580 500V 710A 6 6 URD 31 D 11 0630 Q300026 D600188 Solbrak...

Страница 10: ...Technical Specification Solbrake 17A 105 90 105 75 6 5 4 3 2 1 L2 L1 W V U Solbrake 31 58A 10...

Страница 11: ...Technical Specification Solbrake 105 210A 77 12 20 17 12 12 M6 W L1 L2 U V 280 263 160 Solbrake 310 390A V 63 4 L W V 222 224 W L 384 18 18 L U U L 11...

Страница 12: ...2 10 sec Optionally 1 30 sec Protection Automatic stopped motor sensor Switches off the DC injection automatically when motor has come to a complete stop Indications ON Green Illuminates when power is...