2
Table of Contents
Page Subject
3
Brake selection
4 Installation
Notes
5
Mode of operation
6-7
Wiring and operation
8
Potentiometer settings and Start up
procedure
9
Fuse Selection Table
10 Dimensions
11 Technical
Specification
* Read this manual carefully before operating the equipment and follow its instructions
* Installation, operation and maintenance should be in strict accordance with this manual, national
codes and good practice. Installation or operation not performed in strict accordance with these
instructions will void manufacturer's warranty.
* Disconnect all power inputs before servicing the Solbrake / SMB and/or the motor.
* After installation, check and verify that no parts (bolts, washers, etc) have fallen into the power
Section (IP00).
ATTENTION
1. This product was designed and tested for compliance with IEC947-4-2 for class A equipment.
2. The Solbrake / SMB brakes are designed to meet UL requirements
3. Use of the product in domestic environments may cause radio interference, in which case the user
may be required to employ additional mitigation methods.
4. Utilization category is AC-53a or AC53b. Form1.
5. For further information see Technical Specification
WARNING
* Internal components and P.C.B's are at mains potential when the Solbrake / SMB is connected
to mains.
This voltage is extremely dangerous and may cause death or severe injury if contacted.
* When the Solbrake / SMB is connected to mains, even if operation signal is disconnected full
voltage may appear on Solbrake / SMB's output.
* Unit must be grounded to ensure correct operation, safety and to prevent damage.
* Check that Power Factor capacitors are not connected to the output side of the Solbrake / SMB.