TURN OFF ALL POWER TO EXISTING EQUIPMENT AT THE BREAKER SWITCH.

Ÿ

BEFORE  STARTING  INSTALLATION,  YOU  MUST  READ  THIS  MANUAL  IN  ITS 
ENTIRETY TO ASSURE A SAFE INSTALLATION.  

INSTALLATION

A) Install the Precision into a 1⁸ ¹⁄  inch opening with a union on both sides to facilitate easy removal should it 
become necessary. Unions are provided for easy servicing and removal.
B) Clean the ends of the PVC pipe and glue the manifold into opening in the horizontal position shown above.
C) If existing pipe is sized smaller or larger than 2 inch, use adapters to install manifold (not provided)
D) Water flow is automatically diverted into the UV chamber at the proper flow rates.   Restriction to the 
plumbing is nominal when the manifold is inserted into the plumbing and is comparable to adding a heater to 
the pool. See below:

o

DO  NOT  ATTACH  MANIFOLD  DIRECTLY  TO  A  90   ELBOW.  ALLOW  AT  LEAST  6  INCHES  OF 
STRAIGHT PIPE ON EACH SIDE.

Filter

Skimmer

Water

from

pool

Water

return

to pool

Heater

Manifold

Optional
Salt Cell

(not provided)

To Power

Source

Ÿ

1. PLUMBING:

Install manifold downstream of the heater and before chlorine tablet feeder.   If space allows, install 

manifold minimum two feet away from the heater to avoid possible safety shutdown of the system due to 
hot water conditions in the chamber.  

4

2 Ft.

Unions

(

provided

)

System On 
(Flashing - No Flow)

Check Manual 
or Our Website

www.solaxx.com

PRECISION

PRECISION

Содержание Precision UV

Страница 1: ...Installation and Operating Instructions PRECISION PRECISION www solaxx com PRECISION PRECISION AUTOMATIC REGULATOR FLOW...

Страница 2: ...nit WARNING ELECTRICSHOCK DisconnectallACpowerduringinstallationorperforminganyservicework CAUTION Topreventpossible reorelectricalshock useonlyreplacementlampspeci edbythemanufacturer CAUTION Donotus...

Страница 3: ...e quality of drinking water A microscopic residual of chlorine 5 1 0 ppm is recommended for use with this system as a supplemental source of disinfection For best results the pool pump should run at l...

Страница 4: ...ally diverted into the UV chamber at the proper ow rates Restriction to the plumbing is nominal when the manifold is inserted into the plumbing and is comparable to adding a heater to the pool See bel...

Страница 5: ...LHEALTH A Unthread and remove the end cap with the wire attached from the end of the UV chamber by rst loosening the small black plastic nut then the larger black nut to pull out plug B Pull gently un...

Страница 6: ...ing power supply 2 Mount the aluminum bracket rst on a vertical surface at a height of approximately ve 5 feet above the ground using the screws provided with the spacers against wall to allow air ow...

Страница 7: ...2 inch UL514B 5 Wires 6 Items 3 4 5 Not supplied INSTALLATION 1 2 3 4 5 Ground L1 L2 Line Pump Power Supply Box 240V Install Ground L1 N Line Pump Power Supply Box 110V Install Wires to be connected t...

Страница 8: ...IELD A DEFECTIVE OR NON FUNCTIONING POWER SUPPLY IS REPLACED WITHANEW UNIT ONLY Steady Blue LED system has power and is operating normally Flashing Blue LED no ow to chamber This could be caused by th...

Страница 9: ...the power supply which is mounted to the wall and slide up off of mounting bracket C Unthread the union nuts and remove the entire manifold from the pipe and store safely inside D Cover opening in pi...

Страница 10: ...TTING OILS FROM HANDS ON THE LAMP SKIN OILS ATTACH TO THE LAMP AND SHORTEN ITS EFFECTIVE LIFE IF LAMPISTOUCHED WIPE CLEAN WITHASOFTCLOTHAND RUBBINGALCOHOL CLEANING THE QUARTZ SLEEVE The quartz sleeve...

Страница 11: ...n any respect including but not limited to the use of parts other than genuine manufacturer parts If this System is installed for use on non residential pools or pools bigger than 35 000 gallons this...

Страница 12: ...MAN6000 12 17 PRECISION PRECISION www solaxx com...

Отзывы: