MAINTENANCE

LAMP REPLACEMENT

The UV lamp is rated for 13,000 hours of service and can be monitored through the blue viewing caps at 
the end of the chamber.  

DO NOT VIEW LAMP DIRECTLY - ALWAYS USE VIEWING CAP

. When the 

lamp requires replacement, follow this simple procedure:

Shut off AC power before performing maintenance
Allow lamp to cool for 10 minutes before handling

A. Unthread and remove the end cap with the wire attached from the end of the UV chamber

, by first 

loosening the small black plastic nut, then the larger black nut to remove lamp.

 

B. Plug the 4 prong plug into the end of the UV lamp. If lamp is not fully plugged in, damage to the unit 

may occur.  

C. Slide lamp 

straight

 into chamber - 

Be careful, inserting the lamp at an angle, even a slight angle 

can crack the quartz sleeve.

D. Rethread black cap back onto chamber fitting by hand to assure tight seal.

IMPORTANT:

  

HANDLE THE LAMP BY THE ENDS ONLY AND AVOID TOUCHING THE CLEAR GLASS OF THE 
LAMP.  IF POSSIBLE USE COTTON GLOVES TO HANDLE LAMP TO AVOID GETTING OILS FROM 
HANDS ON THE LAMP.  SKIN OILS ATTACH TO THE LAMP AND SHORTEN ITS EFFECTIVE LIFE.  
IF LAMP IS TOUCHED, WIPE CLEAN WITH A SOFT CLOTH AND RUBBING ALCOHOL.

CLEANING THE QUARTZ SLEEVE

The quartz sleeve inside the UV chamber encases the UV lamp and 
should  be  cleaned  while  winterizing  the  system,  or  annually  if 
system is installed on a pool running 12 months.  The quartz sleeve 
is brittle and can be cracked, chipped or broken if it is not handled 
with care.  Do not remove the sleeve or attempt to scrape or scrub 
the sleeve as it could crack or break it.

-After removing the manifold as shown in WINTERIZING   section,  
unthread  the  top  chamber  and  turn  the  chamber  over  so  the 
openings face up.  
-Using  CLR  or  Lime  Away  or  a  comparable  cleaning  product 
(available at grocery stores or home centers), pour into the chamber 
to cover the quartz sleeve with the liquid and allow to soak for 30 
minutes.   Dispose of cleaning solution by following instruction on 
the cleaning solution container.
-Rinse  the  quartz  sleeve  with  isopropyl  alcohol  to  remove  any 
remaining residue from the sleeve.
-Rinse the sleeve again with water.

C

Fill to here so

quartz sleeve

is covered.

10

Push

A

loosen 

first

loosen 

second

DO NOT

LOOSEN

B

D

Содержание Precision UV

Страница 1: ...Installation and Operating Instructions PRECISION PRECISION www solaxx com PRECISION PRECISION AUTOMATIC REGULATOR FLOW...

Страница 2: ...nit WARNING ELECTRICSHOCK DisconnectallACpowerduringinstallationorperforminganyservicework CAUTION Topreventpossible reorelectricalshock useonlyreplacementlampspeci edbythemanufacturer CAUTION Donotus...

Страница 3: ...e quality of drinking water A microscopic residual of chlorine 5 1 0 ppm is recommended for use with this system as a supplemental source of disinfection For best results the pool pump should run at l...

Страница 4: ...ally diverted into the UV chamber at the proper ow rates Restriction to the plumbing is nominal when the manifold is inserted into the plumbing and is comparable to adding a heater to the pool See bel...

Страница 5: ...LHEALTH A Unthread and remove the end cap with the wire attached from the end of the UV chamber by rst loosening the small black plastic nut then the larger black nut to pull out plug B Pull gently un...

Страница 6: ...ing power supply 2 Mount the aluminum bracket rst on a vertical surface at a height of approximately ve 5 feet above the ground using the screws provided with the spacers against wall to allow air ow...

Страница 7: ...2 inch UL514B 5 Wires 6 Items 3 4 5 Not supplied INSTALLATION 1 2 3 4 5 Ground L1 L2 Line Pump Power Supply Box 240V Install Ground L1 N Line Pump Power Supply Box 110V Install Wires to be connected t...

Страница 8: ...IELD A DEFECTIVE OR NON FUNCTIONING POWER SUPPLY IS REPLACED WITHANEW UNIT ONLY Steady Blue LED system has power and is operating normally Flashing Blue LED no ow to chamber This could be caused by th...

Страница 9: ...the power supply which is mounted to the wall and slide up off of mounting bracket C Unthread the union nuts and remove the entire manifold from the pipe and store safely inside D Cover opening in pi...

Страница 10: ...TTING OILS FROM HANDS ON THE LAMP SKIN OILS ATTACH TO THE LAMP AND SHORTEN ITS EFFECTIVE LIFE IF LAMPISTOUCHED WIPE CLEAN WITHASOFTCLOTHAND RUBBINGALCOHOL CLEANING THE QUARTZ SLEEVE The quartz sleeve...

Страница 11: ...n any respect including but not limited to the use of parts other than genuine manufacturer parts If this System is installed for use on non residential pools or pools bigger than 35 000 gallons this...

Страница 12: ...MAN6000 12 17 PRECISION PRECISION www solaxx com...

Отзывы: