SolaX Power T-BAT H11.2 Скачать руководство пользователя страница 4

Flexible Scheme 

· 8 type of system can be chose.

 

Quality Assurance 

· 

Passed a series  of certifications, eg: 

TUV  (IEC 62619) 

OVERVIEW 

Easy Installation 

· Simple wire connection and fast installation.

 

Содержание T-BAT H11.2

Страница 1: ...Triple Power High Voltage Storage System www solaxpower com...

Страница 2: ...CONTENTS 1 3 4 OVERVIEW INTRODUCTION CERTIFICATION INSTALLATION STATUS INDICATOR TROUBLESHOOTING...

Страница 3: ...ElectricMeter Bidirectional Surge Arrestor Fuse DCBreaker Surge Arrestor Fuse DCBreaker EPS Load Commo nLoad DC Breaker AC Breaker Contactor Battery System Photovoltaicsystem consist of Solar cell mo...

Страница 4: ...Flexible Scheme 8 type of system can be chose Quality Assurance Passed a series of certifications eg TUV IEC 62619 OVERVIEW Easy Installation Simple wire connection and fast installation...

Страница 5: ...ge Cycle Life 6000 Hardware Secondary Protection Classified Protection IP55 Safety Reliable Little Space Taking Two Installation Methods Floor Mounting Wall Mounting For Single Phase Storage Inverter...

Страница 6: ...y Module Energy KWh Voltage V 1 T BAT H4 0 MC0500x1 HV10040X1 4 85 118 2 T BAT H8 0 MC0500x1 HV10040X2 8 170 236 3 T BAT H12 0 MC0500x1 HV10040X3 12 255 354 4 T BAT H16 0 MC0500x1 HV10040X4 16 340 472...

Страница 7: ...rrent A 30 30 30 Recommend Charge Discharge Current A 25 25 25 Standard Power kW 2 5 2 5 Maximum Power kW 3 3 Faradic Charge Efficiency 25 77 99 Battery Round trip Efficiency C 3 25 77 95 Expected Lif...

Страница 8: ...CTION BMS Port Port Lable Description A Breather Valve B XPLUG Power Port Connect with battery module C RS485 RS485 Communication Port D DIP DIP Switch E ON OFF Air Switch F POWER Power Switch G CAN C...

Страница 9: ...Port Port Lable Description A XPLUG Power Port Connect with the next one battery module YPLUG port B RS485 I RS485 communication port 1 Connection with battery module s communication port C GND Connec...

Страница 10: ...Battery pack safety CE FCC RCM TUV IEC 62619 UL 1973 Battery cell safety UL 1642 UN number UN 3480 Hazardous materials classification Class 9 UN transportation testing requirements UN 38 3 Internatio...

Страница 11: ...INSTALLATION Design Sketch...

Страница 12: ...INSTALLATION Complete Installation Drawing...

Страница 13: ...upposed to estimate the GND wire first according to their actual installation site Then connect GND wire with battery module Then start installing floor mounting or Wall mounting Lastly connect power...

Страница 14: ...ION 2 Power Line Connection a Connect Power Line Length 120mm between BMS and Battery Module BMS XPLUG with Slave Controller XPLUG BMS Master Controller Slave Controller Battery Module Slave Controlle...

Страница 15: ...into this batterymodule sYPLUG port when finishing the Power line Communication line connection so that can make a completeelectric loop Note If using 2 4 batterymodules you should use power line Len...

Страница 16: ...INSTALLATION 2 Power Line Connection Actual Connection Diagram...

Страница 17: ...BMS RS485 port and Battery Module sRS485I port then tighten the plastic nut If more than one batterymodule 2 4 Battery Modules after finishing the communication connectionbetween BMS and First batter...

Страница 18: ...INSTALLATION 3 Communication Line Connection CAN Communication Connecting CAN Communication Line Length 2mm between BMS CAN Port and Inverter CAN Port...

Страница 19: ...INSTALLATION 4 GND Connection THIS IS MANDATORY REQUIREMENT Using 10AWG GND line to connect GND Port between BMS and Battery Module then connect with inverter s GND Port in the end...

Страница 20: ...INSTALLATION 5 Charge Line Connection Connectto Inverter Using Power Line Length 2m to complete connections between Inverter and BMS...

Страница 21: ...INSTALLATION 5 Communication Line Connection Connectto BMS Using Power Line Length 2m to complete connections between Inverter and BMS...

Страница 22: ...N 6 Commission a Set theAir Switch to ON b Turn on the Power Switch Note Please make sure the interval time at least exceeding 10 seconds before next time to press button c Turn the Power Switch of th...

Страница 23: ...r No Mode Status of BMS 1 Active Green LED flashes once every 5s 2 Protection Yellow LED flashes once every 5s 3 Fault Red LED flashes once every 5s 4 Configuring Green LED keeps on 5 Upgrade for mast...

Страница 24: ...STATUS INDICATOR BMS Status Indicator Charge Discharge 60 Power...

Страница 25: ...Module 1 Active Green LED flashes once every 5s 2 Warning Yellow LED flashes once every 5s 3 Protection Red LED flashes once every 5s 4 Configuring Green LED keeps on 5 Upgrade for master module Gree...

Страница 26: ...service or your distributor directly BMS_TemHigh Battery over temperature Wait till the temperature of cells go back to the normal state BMS_TemLow Battery under temperature Wait till the temperature...

Страница 27: ...Thank you...

Отзывы: