For lead acid battery, when charging begins, it will enter constant
votlage charging mode in order to accelerate charging speed. The
value can be set for 50-58V.
For lead acid battery, it will switch to oat charging mode after
exiting constant voltage charging mode. The value can be set for
50-58V
Charge
Absorp Voltage
Charge
Float Voltage
Only for lithium battery and its BMS is compatible with inverter’s protocol, the parameter”Min capacity”
need to be set.
Operation Method
47
K) Charger
Here the user can set the parameters of charger ,the inverter is compatible with
Lead acid and lithium batteries. Users can set the battery type, charge and
discharge parameters,awaken mode here.Press up or down button to select and
press“OK” to confirm. For the detailed parameters , please refer to below table.
>Battery type
Lithium
Charger
>Min Capacity
20%
Charger
>Battery awaken
Charger
No
NOTE
!
Please con rm the Inverter setting for maximum charge/discharge
current is within the range of battery rated charge/discharge current.