SOLATHERM STHS 120 Скачать руководство пользователя страница 25

24 

 

SOLATHERM

 reserves the right to modify characteristics of the products or their accessories and components without prior notice. 

 
 

* Solar-Only: only solar energy without back-up heating element or any other source of energy 

  

 

CALCULATIONS ARE EXECUTED ACCORDING TO THE ANNEX D OF SOLAR KEYMARK -    

“SPECIFIC SCHEME RULES”

 

 TESTING LABORATORY NCSR DEMOKRITOS 

 REPORT CODE: 6082-F1 

 
Thermosiphon System: STHS 120/182 
 

Performance Indicators for Solar-Only* Systems on Annual Base for a Demand Value of 110 lt/day 

Location (Latitude) 

Q

d

 (MJ) 

Q

L

 (MJ) 

f

sol 

(%) 

Stockholm (59.2°N) 

6150 

2870 

46.8 

Würzburg (49.5°N) 

5897 

2952 

50.1 

Davos (46.5°N) 

6654 

4226 

63.6 

Athens (38.0°N) 

4573 

3658 

80.0 

 
Thermosiphon System: STHS 160/200 
 

Performance Indicators for Solar-Only* Systems on Annual Base for a Demand Value of 140 lt/day 

Location (Latitude) 

Q

d

 (MJ) 

Q

L

 (MJ) 

f

sol 

(%) 

Stockholm (59.2°N) 

7821 

3311 

42.3 

Würzburg (49.5°N) 

7506 

3500 

46.8 

Davos (46.5°N) 

8483 

4920 

58.2 

Athens (38.0°N) 

5834 

4447 

76.4 

 
Thermosiphon System: STHS 200/200 
 

Performance Indicators for Solar-Only* Systems on Annual Base for a Demand Value of 200 lt/day 

Location (Latitude) 

Q

d

 (MJ) 

Q

L

 (MJ) 

f

sol 

(%) 

Stockholm (59.2°N) 

11164 

3813 

34.2 

Würzburg (49.5°N) 

10691 

4131 

38.6 

Davos (46.5°N) 

12110 

5645 

46.6 

Athens (38.0°N) 

8326 

5550 

66.7 

 
Thermosiphon System: STHS 200/237 
 

Performance Indicators for Solar-Only* Systems on Annual Base for a Demand Value of 200 lt/day 

Location (Latitude) 

Q

d

 (MJ) 

Q

L

 (MJ) 

f

sol 

(%) 

Stockholm (59.2°N) 

11164 

4320 

38.7 

Würzburg (49.5°N) 

10691 

4636 

43.4 

Davos (46.5°N) 

12110 

6433 

53.2 

Athens (38.0°N) 

8326 

6023 

72.4 

 
Thermosiphon System: STHS 300/364 
 

Performance Indicators for Solar-Only* Systems on Annual Base for a Demand Value of 300 lt/day 

Location (Latitude) 

Q

d

 (MJ) 

Q

L

 (MJ) 

f

sol 

(%) 

Stockholm (59.2°N) 

16746 

6623 

39.6 

Würzburg (49.5°N) 

16052 

7190 

44.7 

Davos (46.5°N) 

18165 

9997 

55.1 

Athens (38.0°N) 

12488 

9209 

73.8 

 
Thermosiphon System: STHS 300/400 
 

Performance Indicators for Solar-Only* Systems on Annual Base for a Demand Value of 300 lt/day 

Location (Latitude) 

Q

d

 (MJ) 

Q

L

 (MJ) 

f

sol 

(%) 

Stockholm (59.2°N) 

16746 

6938 

41.5 

Würzburg (49.5°N) 

16052 

7474 

46.6 

Davos (46.5°N) 

18165 

10533 

58.0 

Athens (38.0°N) 

12488 

9492 

76.0 

 

Содержание STHS 120

Страница 1: ...SOLATHERM THERMOSIPHON SYSTEMS TECHNICAL INSTALLATION AND USE MANUAL V1 0 03 17 TECHNICAL INSTALLATION AND USE MANUAL...

Страница 2: ...f 2 00m2 or 2 37m2 page 11 3 Connection details for STHS 120 2 00m2 and 120 2 37m2 Systems page 12 4 Connection details for STHS 160 2 00m2 and 160 2 37m2 Systems page 13 5 Connection details for STHS...

Страница 3: ...vy snow fall or strong winds it may be necessary to further anchor the system to the point of installation In this case it is up to the installer along with the client to determine the best and safe w...

Страница 4: ...e above the formula must be used in order to calculate the coefficient The collectors must face towards the South when installed North of the equator and towards the North when installed South of the...

Страница 5: ...ED THROUGH THE TAP IT WILL PROBABLY MAKE AN UNUSUAL SOUND AS WITH AIR ESCAPING The safety of the system and validity of the warranty are conditioned by the use of genuine SOLATHERM spare parts and acc...

Страница 6: ...ter and less dense than cold therefor by stratification is always at the highest point while cold always sinks below This is why these types of solar systems are referred to as Natural Circulation or...

Страница 7: ...Characteristics Low Iron Mistlite Tempered Solar Glass Security Laser Welded Al Cu Titanium Selective Absorber 5mm Rear Insulation Rock Wool 40mm Copper Headers and Risers Aluzinc Rear Cover of the C...

Страница 8: ...Absorber Treatment Number of Risers Total Area m Aperture Area m Volume lt Weight empty kg EFM150 1480x1010x86 Titanium Selective 9 1 50 1 38 1 21 26 20 EFM150H 1010x1480x86 Titanium Selective 14 1 50...

Страница 9: ...ss 1 5mm 4 Thermal Insulation high density 50kg m ecological CFC free incombustible expansive CFC free polyurethane foam thickness 50mm 4 External casing made of hot dipped galvanized steel with elect...

Страница 10: ...of with Wood Shingles and Shake Roof with Synthetic Roofing Products Sheet Metal roofing Available Mounting Structure Materials Hot dipped galvanized steel Powder coated galvanized steel Aluminium Ava...

Страница 11: ...ITTING FOR 22mm COPPER TUBE 2 4 6 TEE FITTING 3 4 MALE x 3 4 FEMALE x 3 4 FEMALE 1 1 1 7 ELBOW FITTING MALE 1 2 x 1 2 FEMALE 1 1 1 8 MALE PLUG 3 4 1 1 1 9 SAFETY VALVE 2 BAR FOR CLOSE LOOP CIRCUIT 1 1...

Страница 12: ...237 STHS200 200 STHS200 237 C 660mm 660mm 850mm 850mm 940mm 940mm W 1130mm 1385mm 1250mm 1385mm 1490mm 1490mm W C 1 2 3 4 5 6 7 8 1 3 4 2 Step 1 Assemble the Side Brackets using M8x20 Bolts and Nuts 5...

Страница 13: ...on Nr 3 3 Connection details for STHS 120 2 00m2 and 120 2 37m2 Systems 7 M8x30 8 Step 4 Connect the Tank Support Brackets No 7 to the Side Brackets No 1 using the M8x20 and M8x30 nuts and bolts as in...

Страница 14: ...cs of the products or their accessories and components without prior notice 4 Connection details for STHS 160 2 00m2 and 160 2 37m2 Systems 5 Connection details for STHS 200 2 00m2 and 200 2 37m2 Syst...

Страница 15: ...tighten upper Collector Support Bracket Nr 6 with Support brackets Nr 1 Install the Tank making sure the cold water inlet is on the left side when looking at the system from the front Connect the Tank...

Страница 16: ...copper tuber If the copper tube is rotated it can cause damage to the absorber and break the wildings between the vertical tubes risers with the 22 tubes headers which will not be covered by the warr...

Страница 17: ...ited to 50 C SHORT STAINLESS STEEL TUBE INSULATION No 13 BALL VALVE MALE X FEMALE No 11 is installed right after the Safety Non Return Valve No 10 FITTING Nr 6 FITTING No 8 Plug it only after closed l...

Страница 18: ...not to rotate the copper tuber If the copper tube is rotated it can cause damage to the absorber and break the wildings between the vertical tubes risers with the 22 tubes headers which will not be c...

Страница 19: ...he Tap and avoid burning It is recommended that the hot water delivered at the Tap is limited to 50 C FITTING No 4 COPPER TUBE INSULATION No 13 FITTING No 2 FITTING No 6 COLD INLET FITTING No 3 FITTIN...

Страница 20: ...CORP OF THE ELBOW FITTING UNTIL THE TUBE CAN T GO FURTHER IN REPEAT THE SAME THING FOR COPPER TUBE STEP 3 TIGHTEN BOTH NUTS CAUTION TAKE EXTRA CARE ON THE FLEXIBLE TUBE NUT THE THREADS ON THE FITTING...

Страница 21: ...the bucket before the water and mix thoroughly Place the bucket with the mixture above the tank and fill the system through the outlet where the safety valve No 9 or expansion vessel No 14 will be fit...

Страница 22: ...C under the protective cap on the left hand side of the tank on the metallic flange apparatus plate On the same flange one of the 2 magnesium rods anode is also installed picture 1 Note a Electrical...

Страница 23: ...ty sheet and the warranty sheet accompanying must be completed accordingly by the installer All installations and maintenance must be performed by qualified and certified professionals following all r...

Страница 24: ...g valve is not too low below 50 C depending on local regulations 10 If the electric back up is working In case it is not working please check the following That the main power supply is ON That the th...

Страница 25: ...siphon System STHS 200 200 Performance Indicators for Solar Only Systems on Annual Base for a Demand Value of 200 lt day Location Latitude Qd MJ QL MJ fsol Stockholm 59 2 N 11164 3813 34 2 W rzburg 49...

Страница 26: ...anty from the date of purchase 7 The manufacturer assumes no responsibility and the present warranty is invalid in the following cases A When the product has not been checked repaired altered or insta...

Страница 27: ...their accessories and components without prior notice STHS SERIES THERMOSIPHON SYSTEMS TECHNICAL INSTALLATION AND USE MANUAL Version V1 1 17 All rights reserved Text and Illustrations correspond to s...

Отзывы: