12. Place the unit in position within the combustible
framing shown on page 12. The 2x4 steel studs (not
included) will be installed next. The stud length,
dimensions “G” on page 10 can be calculated using
either of the following equations:
Stud Length Equation:
English (inches): Stud Length G = A – 31.375"
Metric (millimeters): Stud Length G = A – 797mm
* Refer to page 10 for Dimension “G” referenced
in the above equations.
13. Once the studs have been cut to length, insert the
studs fully in the collector stud brackets as shown in
“Detail A” above, secure with (4) #10 self-drilling sheet
metal screws per stud.
A
DETAIL A
INSTALLATION